TROUBLESHOOTING
PROBLEM 
POSSIBLE CAUSE 
SOLUTION 
Unit does not operate. 
The controller is not 
communicating with 
the Spectra unit. 
Check to see if the red LED on the circuit 
board in the back box is lit. 
1. The red LED is not lit
a. Fuse is bad. 
b. 24 VAC power source is not con­
nected or back box is bad. 
2. The red LED is lit
a. Wiring is incorrect or is not fully 
seated. 
b. DIP switch settings are incorrect. 
a. Check fuse on the circuit board. Replace fuse if it is 
bad. To order a fuse from Pelco, specify the part 
number FUS1.6-5X20FAST. This is a 1.6-ampere 
fuse, 5 x 20 mm, fast blow. 
b. Use a voltmeter to check if 24 VAC is getting to the 
power connector on the circuit board. If NO, check 
your power supply. If YES, return the back box to 
the factory for repair. 
a. Check all connections to the circuit board. 
Make sure that all connections are fully seated and 
the board is wired correctly. 
b. Check the DIP switch settings on the dome drive 
(refer to Tables C, D, and E). If the unit still does 
not operate, turn off power and replace the dome 
drive with a good unit, if you have a spare. Check 
the switch settings on the substitute dome drive 
before installing it. (If you do not have a spare, 
return the dome drive and back box to the factory.) 
If you substituted a dome drive and the unit 
operates
, the original dome drive is bad (return 
the dome drive to the factory). If the unit still 
does not operate
, then the circuit board is bad 
(return the back box to the factory). 
Fan does not 
operate. 
Fan connections are not fully seated. 
Make sure the connector for the fan is fully seated. If 
the fan still does not operate, return the back box and 
dome drive to the factory for repair. 
Vertical roll on monitor 
when switching 
between cameras. 
Cameras are out of phase. 
DOME 1 
POWER 
DOME 2 
POWER 
DOME 3 
POWER 
If you are wiring more than one dome to the same 
transformer, it is important to wire the power connec­
tor in each dome the same way. That is, the wiring 
from one side of the transformer must be connected 
to the same connector on each dome. 
WARNING: Make 
sure you wire power 
to the outer connec­
tors of the terminal 
block and ground to 
the middle connec­
tor. Otherwise, you 
could damage the 
dome. 
00095 
Pelco Installation Manual C2429M (3/01)