Toshiba LF232*F Instruction Manual

Page of 8
TIC-LF502A
 
 
2
Required straight pipe length: 
10D minimum on upstream side and 
5D minimum on downstream side 
Note: D is a nominal meter size. 
Fluid conductivity: 100µS/cm minimum 
Fluid temperature:  32 to 131 °F  (0 to 55 °C ) 
Ambient temperature: 14 to 122 °F (-10 to 50 °C ) 
Dimensions and Weights: See figures 3 to 5. 
Power supply: 
100 to 120 Vac (80 to 132 Vac), 50/60Hz 
Power consumption: 50VA (30W) or less 
■ 
Model LF502 Detector 
Meter sizes: 6” (150 mm ), 8” (200 mm ), 10” (250 
mm ), 12” (300 mm ), 14” (350 mm ), 16” (400 
mm ), 20” (500 mm ), 24”(600 mm ) 
Fluid pressure:  
0 psi or 0 bar (0 MPa) to the pressure limited by 
flange standard 
(fully-filled condition) 
Connection flange standards:  
ANSI 150, JIS 10K 
Structure:   
IP67 and NEMA 4X Watertight (std. ) 
IP68 and NEMA 6P  Submersible (opt.) 
Coating: Phthalic acid resin coating, pearl-gray 
colored (standard for watertight type) or black tar 
epoxy (option for watertight type and specified 
exclusively for submersible type)  
Principal materials: 
Case — carbon steel 
Measuring pipe — 304 stainless steel 
Linings
 — The following are the standards: 
Meter size 
Standard specification
6” to 16” (150 to 400mm ) 
EPDM rubber 
20” & 24” (500 & 600mm ) 
Chloroprene rubber 
Electrodes — 316L stainless steel (std.) 
Grounding rings — 
The following are the 
standards.
 
Meter size 
Standard specification
6” to 16” (150 to 400mm ) 
316 stainless steel 
20” & 24” (500 & 600mm ) 
304 stainless steel 
See Table 1 for optional materials and other 
related information. 
Coating: phthalic acid resin coating (std.), 
                Pearl-gray colored 
Cable connection port: 
Cable glands: Provided as standard, R(PT) 1/2 
male screw. 
Applicable diameter: 0.433 to 0.512 inch  (11 
to 13mm ) 
■ 
Model LF232*F converter 
Input signals 
Analog signal  the voltage signal from detector, 
proportional to process flow rate. 
Digital input DI (opt.) 
(added when 9
th
 digit of specification code is ”3”) 
Voltage level: High level 20 to 30 V dc 
Low level 2 V dc or less 
Input resistance: 2.7 k
Ω 
Number of inputs: 2 points (DI1 and DI2)
 
DI functions:  
For digital input function, either of the following 
functions can be selected. 
• Range switching  
One Digital Input is used: switching between large 
and small ranges of forward/reverse, 2-range 
measurement. 
Two Digital Inputs are used: switching between 
ranges of single direction, 4-range measurement. 
• Totalizer control input 
  
Totalizer Start/Stop control or Reset/Start 
•Output hold input  
Fixed with set value for current output and pulse 
output (loop check) 
• Zero adjustment  
Starts zero adjustment (on-stream at zero flow rate) 
when DI voltage level goes low after remaining 
high for 10 to 20 seconds. 
Output signals 
Current output: 
4–20mAdc (load resistance 0 to 1K
Ω) 
Digital output (DO) — One point (std.) and three 
more point is optionally available as follows. 
Digital output DO1 (std.):  
Output type: Transistor open collector   
Number of outputs: One point 
Output capacity   : 30Vdc, 200mA maximum 
Digital output DO2DO4 (opt.)  
(Added when 9
th
 digit of specification code is “3”)  
Out put type: Solidstate relay output (non polarity) 
Number of outputs: 3 points 
Output capacity: 150Vdc, 150mA maximum or 
150Vac (peak to peak),  
100mA maximum 
DO functions—Four digital output function, either of 
the following functions can be selected. 
• Totalizer pulse output  
DO1 or DO2 can be selected (Forward direction 
pulse and reverse direction pulse can be assigned