Lantronix Network Hardware 900-598 User Manual

Page of 109
 
 
  7: Line and Tunnel Settings 
PremierWave XC User Guide 
 
48
 
Line Command 
Mode Settings
 
Description 
Serial String 
Enter the Text or Binary string of bytes that must be read on the Serial Line during 
boot time in order to enable Command Mode.  It may contain a time element to 
specify a required delay in milliseconds x, formed as {x}.  Applies only if mode is “Use 
Serial String”.  It may contain a binary character(s) of the form [x].  For example, use 
decimal [12] or hex [0xc]. 
Echo Serial String  Select Enabled or Disabled for Echo Serial String.  Applies only if mode is “Use 
Serial String”.  Select enable to echo received characters back out on the line while 
looking for the serial string. 
Signon Message 
Enter the string of bytes to be sent to the Serial Line during boot time.  It may contain 
a binary character(s) of the form [x].  For example, use decimal [12] or hex [0xc]. 
To Configure Line Settings 
Note:  
The following section describes the steps to view and configure Line 1 settings; 
these steps apply to other line instances of the device. 
Using Web Manager 
 
To configure a specific line, click Line in the menu bar and select Line 1 -> Configuration
 
To configure a specific line in Command Mode, click Line in the menu bar and select Line 1 -
>  Command Mode
Using the CLI 
 
To enter Line 1 command level:  enable -> line 1 
Using XML 
 
Include in your file:   <configgroup name="line" instance="1"> 
 
Include in your file:   <configgroup name="serial command mode" instance="1"> 
Statistics 
To View Line Statistics 
Using Web Manager 
 
To view statistics for a specific line, click Line in the menu bar and select Line 1 -> 
Statistics
Using the CLI 
 
To view Line statistics:  enable -> line 1, show statistics