To Configure Tunnel Serial Settings 
Using Web Manager 
 
To configure the Serial Settings for a specific tunnel, click Tunnel in the menu bar and select 
Tunnel 1 -> Serial Settings
Using the CLI 
 
To enter Tunnel 1 command level:  enable -> tunnel 1 -> serial 
Using XML 
 
Include in your file:  <configgroup name=”tunnel serial” instance=”1”> 
Packing Mode 
With Packing, data from the serial Line is not sent over the network immediately.  Instead, data is 
queued and sent in segments, when either the timeout or byte threshold is reached.  Packing 
applies to both Accept and Connect Modes. 
Table 7-4 Tunnel Packing Mode Settings 
 
Tunnel Packing 
Mode Settings
 
Description 
 
Mode 
Configure the Tunnel Packing Mode.  Choices are: 
 
Disable = Data not packed. 
 
Timeout = data sent after timeout occurs. 
 
Send Character = data sent when the Send Character is read on the Serial Line. 
 
Threshold 
Sets the threshold (byte count). If the received serial data reaches this threshold, then 
the data will be sent on the network.  Valid range is 100 to 1450 bytes.  Default is 512. 
 
Timeout 
Sets the timeout value, in milliseconds, after the first character is received on the 
serial Line, before data is sent on the network.  Valid range is 1 to 30000 milliseconds.  
Default is 1000. 
 
Send Character 
Enter Control Characters in any of the following forms: 
 
<control>J 
 
0xA (hexadecimal) 
 
\10 (decimal). 
If used, the Send Character is a single printable character or a control character that, 
when read on the Serial Line, forces the queued data to be sent on the network 
immediately.   
 
Trailing 
Character 
Enter Control Characters in any of the following forms: 
 
<control>J 
 
0xA (hexadecimal) 
 
\10 (decimal). 
If used, the Send Character is a single printable character or a control character that 
is injected into the outgoing data stream right after the Send Character.  Disable the 