Lantronix Network Hardware 900-598 User Manual

Page of 109
 
 
  7: Line and Tunnel Settings 
PremierWave XC User Guide 
 
49
 
Using XML 
 
Include in your file:  <statusgroup name=”line” instance=”1”> 
Tunnel Settings  
Tunneling allows serial devices to communicate over a network, without “being aware” of the 
devices which establish the network connection between them.  Tunneling parameters are 
configured using the Tunnel menu and submenus. The Tunnel settings allow you to configure 
how the Serial-Network tunneling operates.  Tunneling is available on all serial Lines.  The 
connections on one serial Line are separate from those on another serial port. 
Note:
 
The following section describes the steps to view and configure Tunnel 1 settings; 
these steps apply to other tunnel instances of the device. 
Serial Settings 
This page shows the settings for the tunnel selected at the top of the page and lets you change 
the settings. The Line Settings and Protocol are displayed for informational purposes and must be 
configured from the Line pages. 
Table 7-3 Tunnel Serial Settings 
 
Tunnel Serial  
Settings
 
Description 
 
Line Settings 
 
Protocol 
 
DTR 
Select the conditions in which the Data Terminal Ready (DTR) control signal on the 
Serial Line are asserted.  Choices are: 
 
Unasserted 
 
TruPort = the DTR is asserted whenever either a connect or an accept mode 
tunnel connection is active with the Telnet Protocol RFC2217 saying that the 
remote DSR is asserted. 
 
Asserted while connected = the DTR is asserted whenever either a connect or 
an accept mode tunnel connection is active. 
 
Continuously asserted