Hughes DW6000 User Manual

Page of 174
Appendix B • Installing the indoor equipment using dial-up commissioning
70
1033295-0001 Revision 2
• A functioning 10/100 Ethernet interface installed on at least 
one computer. This is not necessary to commission the 
DW6000, but you must ensure the customer can surf before 
you leave.
• A 6-foot Cat-5 Ethernet cable is supplied to connect the 
DW6000 and the customer’s computer. If a longer cable is 
needed the customer must supply it. Either crossover or 
straight-through Cat-5 Ethernet cable can be used.
• A power strip or surge protector. If one of these is not present, 
proceed with the installation using the wall outlet or other 
power source.
• An analog phone line.
Summary of DW6000 
installation process
The actual DW6000 installation is a 14-step process, beginning 
with the site survey and ending with completing the field service 
order (FSO). Refer to the appropriate antenna installation manual 
for those steps involving antenna installation.
1. Qualify the customer PC with the prequalification tool.
2. Conduct site survey.
3. Customer approves site survey.
4. Assemble indoor equipment. Assemble DW6000 and connect 
to laptop. Power DW6000 and laptop and verify connectivity.
5. Compute pointing coordinates using the DW6000 System 
Control Center.
6. Assemble the antenna. Pre-set elevation and polarization 
values.
7. Mount the satellite antenna. 
8. Run cables and ground the system. Clearly label the receive 
and transmit coaxial cables at the antenna, ground block, and 
indoor unit connectors.
9. Receive point the antenna using the SBC interface.
Note:
If the customer wants to connect a network to the 
DW6000, he or she must do so via an Ethernet hub or other such 
equipment. The customer must supply and configure the hub and 
cables. IP address information is provided during commissioning.
Note:
Sometimes the unit must be configured via the Installer 
Console for various reasons. Only units installed for enterprise 
customers can be configured via the Installer Console. The 
installation specification will note when SBC or dial-up 
commissioning is not available. In those cases, follow the 
instructions in Appendix C – Installing the DW6000 using 
Installer Console,
 on page 95
.