Hughes DW6000 User Manual

Page of 174
Appendix B • Installing the indoor equipment using dial-up commissioning
1033295-0001 Revision 2
71
10. Auto cross pol the antenna. When the antenna is locked in 
place and continues to pass isolation, finish weather sealing 
the coaxial cable connections.
11. Register the DW6000 using Websetup. User should be 
present to supply SAN and password and click to agree to 
subscriber agreement.
12. After verifying DW6000 has finished downloading, connect 
the customer’s PC to it. Customer should use power strip or 
surge protector. Customer checks that TCP/IP setting are set 
to obtain an IP address automatically and restarts their 
computer.
13. Customer verifies connectivity by surfing to a Web site.
14. Record site ID and assigned IP address(es) for the customer 
on the Quick Start Guide. Clean up trash and verify 
connections are weather proofed. Optional: assist in customer 
computer configuration.
15. Complete FSO within 24 hours.
Final installation check 
requirements
Before leaving confirm the following items:
Software Download Status
 in the User Interface must show 
“All files are up-to-date."
• The installer has surfed using the user's computer to at least 
the myDIRECWAY site or another Internet site after the 
Software Download Status
 shows "All files are up-to-date."
• The customer’s 
System Information
 page printed out and 
the site ID, Gateway ID, and subnet mask recorded on the 
Quick Start Guide.Help the customer create a browser 
shortcut to the System Control Center. If necessary rename 
the shortcut "System Control Center."
• Help the customer download the DW6000 User Guide from 
myDIRECWAY.com.