Hughes DW6000 User Manual

Page of 174
Chapter 2 • Installing the indoor equipment
1033295-0001 Revision 2
17
Obtain IP address and test
Ethernet connection
1. Restart the PC so it obtains an IP address from the DW6000. 
Or use the command 
ipconfig /renew
 from a DOS 
command line prompt.
2. The embedded DHCP server assigns IP address = 
192.168.0.2 to the PC. The default Gateway address is set to 
192.168.0.1. Figure 12 shows a sample Windows TCP/IP 
Properties screen. (These may vary among different Windows 
operating systems.)
Make sure the installer PC can communicate with the DW6000 
over the Ethernet connection. Enter 
Ping <192.168.0.1>
 at a 
DOS prompt. Figure 13 shows a successful attempt; Figure 14 
shows an unsuccessful attempt. If the PC fails to ping the 
DW6000
, there are issues with either the PC’s NIC or TCP/IP 
configuration.
Note:
In countries outside North America, the DW6000 may be 
plugged, with a physical adapter, directly into a 220 V outlet. 
Different countries may have different standards and requirements. 
Note:
Whenever the LEDs do not function properly as described 
above, check to be sure you have the correct power supply, PN 
1031105-0001.
Figure 12: