Status Monitor
28                    
RP90 Plus E and RL90 User Guide
Controls for viewing or changing magnetic stripe settings.
—  Number of Retry, which sets the maximum number of retries when writing or 
reading magnetic stripe data fails. Default value is 1.
—  ISO Mode, which sets the power used by the magnetic card encoder. The 
default is Hi-Co.
A control to enable or disable the buzzer.
A control to set power saving, which reduces the temperature of the retransfer heat 
roller after the printer is not used for 30 minutes. The default is Disable.
Controls to specify the smart card module(s) (IC Encoder) in the printer.
Retransfer tab
The Retransfer tab shows:
Two matrices for setting the retransfer speed 
and temperature. Click a square to choose the 
setting. On the printer, press the 
Reset
 button 
and then the 
Enter
 button to initialize the 
printer and make the new setting take effect.
The card type, set on the Media Setting tab.
The Refresh button which displays the current 
printer data.
Tips for success
The transfer power to the card gets stronger 
towards the upper right, but the card becomes 
more distorted due to the heat.
Changing the retransfer temperature on one card side also affects the other side.
The range of values changes with the Card Type setting.
Make sample cards to verify settings before using new settings.
Bend Remedy tab
The Bend Remedy tab shows:
A matrix for setting the bend remedy time and 
temperature. Click a square to choose the 
setting. On the printer, press the 
Reset
 button 
and then the 
Enter
 button to initialize the 
printer and make the new setting take effect.
The card type, set on the Media Setting tab.
Tips for success
Bend remedy is effective for single side 
printing. For double side printing, choose the 
Disable
 button.
When you change to Disable, the printer goes 
into 
Preheat
 state for about 10 minutes while 
the roller temperature drops. Wait until the printer state changes to 
Ready
.
The side of the card where bend remedy is performed can become faded.
Make sample cards to verify settings before using the new settings.