Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
 
40 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
3.2.16  Robofon (Message Type j)  
SIA Mode Description 
Robofon 
Example 
<LF><CRC><j><sequence#><receiver#><line#>[#aaaaaa|EE]<CR> 
 
Table 65: 
Robofon (Message Type j) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999.  
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages.  
account # 
The communicator's account number has up to six digits.  
EE 
Event code.   
 
3.2.17  Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g)  
SIA Mode Description 
4-16-1 Example 
<LF><CRC><g><sequence#><receiver#><line#> 
[#aaaaaa|CCCCsCCCCsCCCCsCCCCsC]<CR> 
 
Table 66: 
Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
g  
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999.  
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages.  
Account# 
The communicator's account number has up to six digits.  
CCCC 
Channels 1 to 4.  
One space.  
CCCC 
Channels 5 to 8.  
One space.  
CCCC 
Channels 9 to 12.  
One space.   
CCCC 
Channels 13 to 16.  
One space.   
Supervisory channel.