Bosch Appliances Network Router D6100 User Manual

Page of 168
Conettix D6600/D6100 | Computer Interface Manual | 3.0  
Computer Communication Protocols 
 
 
42 
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 
 
3.2.19  Seriee DTMF (Message Type l)  
SIA Mode Description 
Seriee DTMF 
Example 
<LF><CRC><l><sequence#><receiver#><line#>[#aaaa|*data]<CR> 
 
Table 70: 
Seriee DTMF (Message Type l) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
l (lowercase L). 
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999.  
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 
to 99. The receiver uses Line 0 (zero) for internal messages.  
account # 
The communicator's account number has four digits.  
Data separator.   
Data 
DTMF Seriee Data.   
 
3.2.20  Seriee FSK (Message Type k)  
SIA Mode Description 
Seriee FSK 
Example 
<LF><CRC><k><sequence#><receiver#><line#>[#aaaaa|EZZ]<CR> 
 
Table 71: 
Seriee FSK (Message Type k) Byte Description 
 
Title Description 
LF 
Standard line feed character.  
CRC 
Cyclical redundancy check number.  
Message Type 
k  
sequence# 
The message sequence number. The valid sequence number range is 0001 to 9999.  
receiver# 
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.  
line# 
(Line/Group #) 
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 
99. The receiver uses Line 0 (zero) for internal messages.  
Account # 
The communicator's account number has up to six digits.  
Event code.   
ZZ 
Zone number.