Bosch NGM5064UC Owner's Manual

Page of 64
English 10
Operation
About the Appliance
Use the cooktop for surface cooking applications such as 
boiling, frying, simmering, steaming and sauteing.
Operation
WARNING: 
The burning of gas cooking fuel can create 
small amounts of Carbon Monoxide, Benzene, 
Formaldehyde and Soot. To minimize exposure 
to these substances, the burners should be 
adjusted by a certified installer or agency to 
ensure proper combustion. Ensure proper 
ventilation with an open window or use a 
ventilation fan or hood when cooking with Gas. 
Always operate the unit according to the 
instructions in this manual.
The cooktop has one control knob for each burner. Push 
down and turn to the desired heat setting.
Normal Operation (Electronic Ignition/
Reignition)
The cooktop uses electronic igniters to light the burners. 
There is no pilot light. Each burner has its own igniter. If a 
burner flame blows out during use, the burner will 
automatically reignite.
CAUTION: 
Do not touch any of the burners when the 
cooktop is in use. All ignitors spark when any 
single burner is turned ON or the reignition 
system is activated.
The ignitor should be clean and dry for proper operation.
Avoid getting water or food on the igniter.
If the igniter is wet or soiled, it may spark without 
igniting the burner, or even spark continuously when a 
flame is present.
NOTE: 
If the burner does not light within 4 seconds, turn the burner 
off. Check to see that the cap is positioned correctly on the 
burner base and the igniter is clean and dry. If a burner still 
fails to ignite, see “Before Calling for Service” on page 14.
When a flame is present and a Low setting is used, the 
igniter may occasionally spark. This is normal.
In the Event of a Power Failure
In the event of a power failure, the burners can be ignited 
manually. If the cooktop is being used when a power failure 
occurs, turn all the burner control knobs to the OFF 
position. The burners can then be ignited manually by 
holding a match at the ports and turning the control knob to 
the HI position. Wait until the flame is burning all the way 
around the burner before adjusting the flame to the desired 
height.
WARNING: 
The reignition feature will not work in the event 
of a power failure. 
Typical Flame Characteristics
The burner flame should be blue in color and stable with no 
yellow tips, excessive noise or fluttering. It should burn 
completely around the burner cap.
Foreign particles in the gas line may cause an orange 
flame during initial use. This should disappear with use. 
Check burner to make sure port holes are not obstructed. If 
the ports are clogged, see “Before Calling for Service” on 
page 14
.
 Figure 10: Checking Flame Characteristics
Yellow Flames:
Further adjustment is required. 
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or 
mostly yellow, verify that the 
regulator is set for the correct fuel. After adjustment, 
retest.
Some yellow streaking is normal during the initial start-
up. Allow unit to operate 4-5 minutes and re-evaluate 
before making adjustments.