Bosch Appliances Home Security System DS7400XIV4-EXP User Manual

Page of 40
DS7400XiV4-EXP | User Guide | 11.0  
The Master Keypad (Text Keypad Only) 
EN | 31 
 
 
Bosch Security Systems | 6/05 | 4998154961B 
 
11.0  The Master Keypad (Text Keypad Only) 
11.1 General 
Information 
Your system can include a Master Keypad.
 A Master Keypad is a text keypad programmed to provide access to 
all areas assigned to you, not just the area in which the Master Keypad is located. This is different from a standard 
keypad because standard keypads provide access only to the single area in which they are located. Commands 
entered at the Master Keypad affect all the areas to which you have access. If this is not desirable, the Master 
Keypad can control each area individually using Single Partition Mode. Single Partition Mode allows you to 
control any or all of the areas to which you have access on an individual (one by one) basis (refer to Section 11.3 
Single Partition Mode
). 
 
 
 
To use the Master Keypad, your PIN must be assigned to the area in which the Master Keypad is 
located. 
 
11.2  Master Keypad Displays 
Master keypad displays differ slightly from standard keypads. The Master Keypad display scrolls the status of each 
area, followed by the area number. For example, if all areas are armed, the Master Keypad scrolls through the 
following displays: 
 
Armed  
area 1 
Armed  
area 2 
Armed  
area 3 
Armed  
area 4 
Armed  
area 5 
Armed  
area 6 
Armed  
area 7 
Armed  
area 8 
 
If only areas 1, 2, 3, 4, 6, and 8 are armed, the Master Keypad scrolls through the following displays: 
 
Armed  
area 1 
Armed  
area 2 
Armed  
area 3 
Armed  
area 4 
Ready to 
Arm area 5 
Armed  
area 6 
Ready to 
Arm area 7 
Armed  
area 8 
 
Areas that are not ready display as “Not Ready.” 
Table 30 helps you understand what each LED function of the Master keypad represents. 
 
Table 30: Master Keypad LEDs 
 
 
 
 
LED Off 
Flashing 
On 
Armed 
(red) 
All areas are disarmed. 
One or more areas are armed, or 
an alarm occurred. 
All areas are armed, and no alarms 
occurred. 
Status 
(green) 
Not ready to arm (if the Armed LED 
is on, all areas are armed). 
One or more zones are 
bypassed. 
All areas are ready to arm. 
Power 
(green) 
The control panel lost all power; no 
AC or battery. 
Control panel problems exist. 
Refer to Section 9.0 Error 
Displays
 on page 25
Normal Operation. The control panel is 
running on AC power with no problem. 
Fire 
(red) 
There are no fire alarms. 
A fire zone is in alarm. 
A fire trouble condition exists.