Programmer and Accessory Connections 
 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
61 
 
13.0  Programmer and Accessory 
Connections 
13.1 Programmer 
Connector 
Refer to the D5200 Operation Manual  
(P/N: 74-06176-000) for complete information on using 
the D5200 programmer.  
To connect and disconnect the programmer: 
1.  Lock the Reset Pin (Figure 30). 
2.  Connect the D5200 Data/Power cord to the 
programming connector on the control panel 
(Figure 31). 
3.  Perform the desired programming function (send 
or receive program). 
4.  Disconnect the programmer. 
 
Figure 30:  Reset Pin 
Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
32
31
30
29
1
2
 
1 -  Reset Pin locked (closed) 
2 -  Reset Pin normal (open) for normal control 
panel operation 
 
13.2  Programmer Access Reports 
When a program is sent to the control panel, the 
control panel sends a 
Prog Access OK
 report 10 
seconds after the handler exits or when the 
programmer disconnects. The prompt in routing must 
be programmed 
Yes to send this report. 
13.3 Accessory 
Connector 
Use the accessory connector to connect the control 
panel to the D928 Dual Phone Line Switcher. The 
accessory connector is on the bottom right corner of 
the I/O board (Figure 31). The D928 lets the control 
panel use two telephone lines to send reports. 
Refer to Section 7.11 D928 Dual Phone Line Switcher on 
page 29 for installation and operating instructions. 
Figure 31:  Programmer and Accessory 
Connections 
26
25
NEX IN 2
NEX POWER +
24
ONEX COMMON
23
GRN
D5200/D5360
PROG CONN
1
2
 
1 -  Accessory connector 
2 -  Programming connector