Bosch Appliances Home Security System D9412GV2 User Manual

Page of 74
D9412GV2/D7412GV2 | Operation and Installation Guide | 14.0  
Faceplates 
 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
63 
 
 
14.2 D7412GV2 
Faceplate 
 
Figure 33:  D7412GV2 
TELCO
RING
TIP
PHONE LINE
   SEIZED
EARTH GROUND
COMMON
RELAY A
RELAY B
RELAY C
+ AUX POWER
CLASS 2 TRANSFORMER
16.5 VAC 40 VA 60 Hz
Model D1640
Internally Fused - Do Not short
Requires Unswitched Outlet
Do Not Share With Other Equipment
GROUND FAULT DETECT
Enabled
Disabled
Digital Alarm Communicator Transmitter
Refer to D9412GV2/D7412GV2 Approved Applications Compliance Guide (P/N: F01U003639___)
For System Wiring Diagram, Issue A
Refer to D9412GV2/D7412GV2 Approved Applications Compliance Guide (P/N: F01U003639___)
For Compatible Smoke Detectors
D7412GV2 Control/Communicator is UL Listed for Central Station, Local, Remote Station and
Household Fire Alarm, and Central Station, Local, Police Station Connect, Household Burglar Alarm
and Encrypted Line Security when communicating via a network.
System is intended to be checked by a Qualified Technician at least every 3 years.
The types of initiating circuits for which the control panel has been approved are A, M, W, SS.
VOLTAGE RANGES
Open
3.7 - 5.0 VDC
Normal
2.0 - 3.0 VDC
Short
0.0 - 1.3 VDC
Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
ZONEX OUT 1
ZONEX IN 1
N.F.P.A.
Style 3.5
Signaling
Line
Circuits
F01U003799B
LEDs Off When Normal
Charging Status
Low Battery - 12.1 VDC
YEL
RED
10.2 VDC - Battery Load Shed
This equipment should be installed in accordance with the NFPA 70 (National Electrical Code)
and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station, Proprietary and
Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction
(National Fire Protection Association, Battermarch Park, Quincy, MA 02269). Printed information
describing proper installation, operation, testing, maintenance, evacuation planning and repair
service is to be provided with this equipment.
D7412GV2
NOT USED
26
25
NOT USED
ZONEX POWER +
24
ZONEX COMMON
23
SDI Connector
BATTERY NEGATIVE ONLY
BATTERY POSITIVE ONLY
CAUTION: 
See D9412GV2/D7412GV2 Operation and Installation Guide
WARNING!
Multi-Battery installation requires
Model D122/D122L Dual Battery
Harness. Improper installation can
be a fire hazard.
Battery: Replace every 3 to
5 years with one or two Model
D126 12V 7Ah or D1218
12V 18Ah Lead Acid Batteries.
12
11
13
Point 1 Point 2
15
14
16
Point 3 Point 4
18
17
19
Point 5 Point 6
21
20
22
Point 7 Point 8
PHONE
LED
RED
ON when
communicating
OFF when idle
PHONE LINE SEIZED
TIP
RING
TELCO CORD
MODEL D161
PROGRAMMABLE
ALARM OUTPUTS
Terminals
SWITCHED AUX
and
6
7
Terminal
8
POWER SUPPLY REQUIREMENTS
The Power Supply provides a maximum of 1.4 Amps for the Control Panel and all
Accessory Devices. For System Loading, refer to D9412GV2/D7412GV2
Operation and Installation Guide (P/N: F01U003641___).
(P/N: F01U003641) for Power Requirements relating to Terminals  6  and  7  .
All external connections except Terminal  5  (battery positive) are inherently power
limited. Requirements for battery standby time might reduce allowable output.
GRN
Point 8
S3 Option
Closed = 1K
Ω
 EOL
Normal Operation
Open =AB-12 UL
Bell Box 220 K
Ω
D5200/D5360
PROG CONN
26
24
23
CAUTION:
 Avoid damage to Panel.
Do not connect 24 V to terminals.
Maximum charging current 1.4 A
10
11
7
8
9
6
5
4
2
3
1
 
1 -  Charging status LED (yellow) 
2 -  Low battery LED (red) 
3 -  Color-coded battery leads 
4 -  Ground fault detect enable 
5 -  Phone LED (red) 
6 -  Telephone cord connector 
7 -  Point 8 ground fault detect enable/disable 
8- 
Operation monitor LED (green) 
9- Accessory 
connector 
10- Programming connector 
11- Reset pin