Bosch Appliances Home Security System CC880 User Manual

Page of 32
CC880/LP880, SC8016 | Operators Guide | 17.0 
Reset Latching Outputs 
EN | 13 
 
 
Bosch Security Systems | 6/04 | 920036O.OG.162 
 
17.0  Reset Latching Outputs 
This feature is only applicable if your installer 
programmed an output to latch (remain on) until you 
acknowledge the event that occurred. 
How to Reset Latching Outputs 
Press and hold button [7] until two beeps are heard. 
The output resets. 
18.0 Testing 
Use the testing functions to verify your system is 
operating correctly. 
Horn Speaker Test 
Press and hold button [1] until two beeps are heard. 
The horn speaker sounds for 2 seconds. 
Bell Test 
Press and hold button [2] until two beeps are heard. 
The bell output operates for 2 seconds. 
Strobe Test 
1.  Press and hold button [3] until three beeps are 
heard. The strobe flashes. 
2.  Press and hold button [3] until two beeps are 
heard. 
The strobe stops flashing. 
Walk Test Mode 
Use the Walk Test Mode to test detection devices to 
ensure they are operating correctly. Every time you 
test a zone, the codepad sounds one long beep and 
the horn speaker sounds one short beep to indicate 
the zone is activated when testing. 
1.  Enter your four character master code, followed 
by [4] and the [#] button (for example,  
[2 5 8 0 4 #]). 
Three beeps are heard and the STAY and 
AWAY indicators flash. The codepad beeps 
once every second while the system is in Walk 
Test Mode. 
2.  Activate all zones that require the test.  
3.  When you finish testing all required zones, press 
the [#] button to exit this mode. Two beeps are 
heard and the STAY and AWAY indicators turn 
off. The system returns to the disarmed state. 
19.0  Event Memory Recall 
Use this function to replay back the last 40 events 
that occurred to the system. The event memory 
history replays all alarms and arming/disarming of 
the system in AWAY Mode, STAY Mode 1, and 
STAY Mode 2. However, the system cannot 
differentiate between arming the system in STAY 
Mode 1 or STAY Mode 2. 
How to Enter Event Memory 
Enter your four digit master code, followed by [3] 
and the [#] button (for example, [2 5 8 0 3 #]). 
Three beeps are heard. The last 40 events display 
one at a time by the codepad indicators starting with 
the most recent event. A beep is heard as each event 
displays. 
20.0 Day Alarm 
Day alarm allows a combination of zones to be 
monitored during the disarmed state by beeping the 
codepad buzzer. Only your installer can program 
zones 1 to 4 to operate for day alarm. 
Example 
A day alarm can be set-up at the front door of a shop 
with a pressure mat or electronic beam that 
customers activate as they enter and exit the shop. As 
the customers walk onto the pressure mat or break 
the electronic beam, the codepad buzzer beeps. 
How To Turn Day Alarm On and Off (Software 
Version 1.10 Only) 
Enter your four character master code followed by 
[7] and the [#] button (for example, [2 5 8 0 7 #]). 
Three beeps are heard when you turn the day alarm 
on. Two beeps are heard when you turn the day 
alarm off. 
How To Turn Day Alarm ON (Version 1.20+) 
Press and hold button [4] until three beeps are heard. 
Day alarm turns on. All zones programmed for day 
alarm operation cause the codepad buzzer to beep 
during the disarmed state when activated. 
How To Turn Day Alarm Off (Version 1.20+) 
Press and hold button [4] until two beeps are heard. 
Day alarm turns off. 
 
If your security company programs an 
output to latch on when a day alarm zone 
faults (unseals), pressing the [#] key once 
resets the output.