Bosch Appliances Home Security System CC880 User Manual

Page of 32
CC880/LP880, SC8016 | Operators Guide | 21.0 
Codepad ID and Buzzer Tone 
EN | 14 
 
 
Bosch Security Systems | 6/04 | 920036O.OG.162 
 
21.0  Codepad ID and Buzzer 
Tone  
If you press and hold down button [8], the tone of 
the codepad buzzer changes. There are 50 different 
tones to choose from between 1500 Hz and 5000 Hz. 
If multiple codepads are installed, each codepad can 
have a different tone. 
If the system is partitioned into multiple areas, the 
codepad displays the area that it is assigned to before 
the tone of the buzzer starts to change. 
Table 13:  Codepad ID and Buzzer Tone Change 
 
Zone Indicator 
Area Assigned 
None Not 
Assigned 
1 Area 
2 Area 
3 Area 
4 Area 
Master Partitioned Keypad 
22.0 Partitioning 
Your control panel can be partitioned or split into 
four individual areas. Each areas can be operated 
from one master partitioned codepad, or from 
separate area addressable codepads. 
22.1  Master Partitioned Codepad 
Indicators 
The indicators on a master partitioned codepad are 
configured into four groups (such as, Zone 
Indicators, Area On/Off Display, Area Display, and 
Status Indicators). Refer to Figure 7. The following is 
a description of what the indicators mean. 
Figure 7:  Master Partitioned Codepad 
 
22.1.1 Zone 
Indicators 
Zone indicators 1 to 8 show the status of each zone. 
These zones belong to the area that displays the 
AREA DISPLAY indicator. (For example, if an 
indicator is displayed, that zone is unsealed. If the 
indicator is not displayed, that zone is sealed.) 
22.1.2 
Area On/Off Indicators 
The group of four AREA ON/OFF indicators display 
the status of each area. (For example, if an indicator 
is displayed, that area is armed. If the indicator is not 
displayed, that area is disarmed.) 
22.1.3 
Area Display Indicators 
The group of four AREA DISPLAY indicators show 
which area the zones displayed belong to. All 
functions entered at the keypad only affect the area 
the keypad displays in the AREA DISPLAY. Press 
the [#] key to toggle between each area. 
22.1.4 Status 
Indicators 
A group of four indicators display the following: 
AUX Indicator 
Displays when the control panel is using the 
telephone line communicating with the receiving 
party. 
MAINS Indicator 
Displays the status of the AC mains power. (For 
example, if the indicator is illuminated, the AC 
mains power supply is normal. If the indicator is 
flashing, the AC mains power supply is disconnected 
or failed.) 
FAULT Indicator 
Displays the status of the fault register. (For example, 
if the FAULT indicator is flashing, the system 
detected a fault that was not acknowledged. If the 
FAULT indicator is illuminated, the fault is 
acknowledged. If the FAULT indicator is not 
illuminated, the system has no faults.) 
PARTIAL Indicator 
Only displays for an area armed in STAY Mode 1. 
(For example, if the PARTIAL indicator displays, an 
area is armed in STAY Mode 1. If the PARTIAL 
indicator does not display, no areas are armed in 
STAY Mode 1.) 
22.2  Operation of Codepads in 
Partitioning 
Area Addressable Codepad Operations 
If you have a system that is partitioned with area 
addressable eight zone codepads, the operating 
procedure is exactly the same as described for a non-
partitioned system except that all operations only 
relate to the area the codepad is assigned to. 
Master Partitioned Codepad Operations 
If you have a system that is partitioned with a master 
partitioned codepad installed, the operating 
procedure is exactly the same as described for a non-
partitioned system, except that all operations only 
relate to the area displayed by the AREA DISPLAY 
indicator.