26.3.5Operation
The two LEDs on the fiber interface provide 
information about the status of the fiber interface.
26.4 Installation
The fiber interface can be attached to a wall or any 
other flat surface using a bracket (see figure 26.10). The 
distance between the holes in the bracket is 40 mm.
Mounting of this bracket and the unit on a drywall sheet 
construction requires screws with a minimum screw 
length of 22 mm (7/8") and a minimum diameter of 
2.5 mm (3/32"). Mounting was evaluated for use on a 
drywall surface only.
table 26.5: Status LED indications
Yellow
(Fault)
Green
(Power)
Status
Off
Off
Off; no external power 
available.
On
Off
Stand-by; external power to 
POF switched off.
On
On
Operating; external power to 
POF switched on.
Off
On
Operating; no external power 
available, but powered from the 
POF side.
Off
Blink
Fault, no external power 
available and no protocol 
received.
On
Blink
Fault, external power available, 
but no protocol received.
Note
The PRS-FINNA cannot detect if the correct 
protocol is received. Therefore, its green LED 
does not show the fault status of table 26.5.
figure 26.10: Installation