D9412GV2/D7412GV2 | Program Entry Guide | 7.0  RADXAXS 
EN | 149 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
D# Access Granted? 
D# Enter Request? 
Default: 
No 
Default: 
No 
Selection: 
Yes or No 
Selection: 
Yes or No 
Yes 
Access Events from this door 
controller are sent to the control 
panel for processing. 
A Door RTE Event from this door 
controller is sent to the control panel 
for processing. 
Yes 
No 
Access Events from this door 
controller are not sent to the control 
panel for processing. 
A Door RTE Event from this door 
controller is not sent to the control 
panel for processing. 
No 
This program item determines if RTE Events are sent 
to the control panel for processing memory, printing, 
and remote reporting. 
This program item determines if Access Granted and 
Door Request Events are sent to the control panel for 
processing memory, printing, and remote reporting. 
 
 
A successful Access Event can be 
started by a(n): 
•  Valid user ID 
•  Valid door state changed at the 
keypad. 
•  Automatically scheduled or armed 
state change that holds a door open 
•  RTE or REX. 
D# No Entry? 
Default: 
No 
Selection: 
Yes or No 
Yes 
Access Denied Events from this 
door controller are sent to the 
control panel for processing. 
No 
Access Denied Events from this 
door controller are not sent to the 
control panel for processing. 
This program item determines if No Entry Events are 
sent to the control panel for processing memory, 
printing, and remote reporting. 
 
 
A No Entry Event can be caused by: 
•  Invalid or unknown user ID, interlock 
or secured door, or incorrect authority 
level 
•  RTE or REX at an interlocked door. 
•  RTE or REX at a door in the secured 
mode. 
 
RTE Events require D# Access Granted 
to be programmed as Yes
 
D# Exit Request? 
Default: 
No 
Selection: 
Yes or No 
A Door REX Event from this door 
controller is sent to the control panel 
for processing. 
Yes 
A Door REX Event from this door 
controller is not sent to the control 
panel for processing. 
No 
This program item determines if REX Events are sent 
to the control panel for processing memory, printing, 
and remote reporting. 
REX Events require D# Access Granted 
to be programmed as Yes