White Rodgers 1E78-144 White-Rodgers 70 Series Non-Programmable Single Stage Thermostat Installation Instruction

Page of 8
www.white-rodgers.com
Symptom
Possible Cause
Corrective Action
Heat, Cool or Fan Runs Constantly.
Possible short in wiring.
1. 
Possible short in thermostat.
2. 
Possible short in heat/cool/fan system.
3. 
FAN Switch set to Fan ON.
4. 
Check each wire connection to  verify they are not                                                                
shorted or touching together. No bare wire should 
stick out from under terminal screws. Try resetting 
the thermostat as described above. If the condition  
persists the manufacturer of your system or 
service person can instruct you on how to test 
the Heat/Cool system for correct operation. If the 
system operates correctly, replace the thermostat. 
Furnace Cycles Too Fast or Too Slow
(narrow or wide temperature swing)
The location of the thermostat and/or the size of 
1. 
the Heating System may be  
influencing the cycle rate.
Digital thermostats normally provide precise  
temperature control and may cycle faster than 
some older mechanical models. A faster cycle rate 
means  the unit turns on and off more frequently 
but runs for a shorter time so there is no increase 
in energy use. If you would like to increase the 
cycle time, clip Jumper W-905 as mentioned in the 
instructions for Hydronic Heating Systems. It is not 
possible to shorten the cycle time. If an accept-
able cycle rate is not achieved as received or by 
clipping W-905 contact a local service person for 
additional suggestions.
Cooling Cycles Too Fast or Too Slow  
(narrow or wide temperature swing)
The location of the thermostat and the size of 
1. 
the Cooling System can influence the cycle rate. 
The cycle rate for cooling is fixed and can not be 
adjusted. Contact a local service person for sug-
gestions.   
Thermostat Setting and Thermostat  
Thermometer Disagree
Thermostat thermometer setting requires adjust-
1. 
ment.  
The thermometer can be adjusted +/- 3 degrees. 
See Temperature Display Adjustment in the 
Operation section.
Blank Display and/or Keypad 
Not Responding
Voltage spike or static discharge.
1. 
Battery change required.
2. 
Replace batteries and check heat/cool system
 
for proper operation. If a voltage spike occurs use  
the Reset Operation listed above.
7
  TROUBLESHOOTING              
CONTINUED FROM FIFTH PAGE