White Rodgers 1F82-0261 User Manual

Page of 12
6
Emergency System
EMER bypasses the Heat Pump to use the heat source wired 
to terminal W2 on the thermostat. EMER is typically used when 
compressor operation is not desired, or you prefer back-up 
heat only.
1.   Move SYSTEM switch to EMER position, EMER will fl ash 
on the display.
2.   Press 
 to adjust the thermostat above room temperature. 
The Aux heating system will begin to operate. The Flame 
icon ( ) will display fl ashing to indicate that the Aux system 
is operating.
3. Press 
 to adjust the thermostat below room temperature. 
The Aux heating system should stop operating.
Cooling System
1.  Move SYSTEM switch to COOL position.
2. Press 
 to adjust thermostat setting below room 
temperature. The blower should come on immediately on 
high speed, followed by cold air circulation. 
3. Press 
 to adjust temperature setting above room 
temperature. The cooling system should stop operating.
4 & 5) Select Cycle Rate Selection - The factory default 
setting is (FA, CR) for all modes (Heat Pump, Heat Pump 
Aux, Heat and Cool, Single Stage Heat and Single Stage 
Cool). To change to slow cycling (SL, CR), press the 
 
and 
 keys to toggle between FA & SL. 
 
The cycle rate differentials for different settings are:
 
 
MODE  
Fast 
  Slow
 
 
 
 
FA 
SL
   Heat 
Pump 
1.2°F 1.7°F
   HP 
Aux 
 
0.8°F 1.2°F
   SS 
Heat 
 
0.8°F 1.2°F
   SS 
Cool 
 
1.2°F 1.7°F
6)  Select Compressor Lockout CL OFF or ON - Selecting 
CL On will cause the thermostat to wait 5 minutes between 
cooling cycles. This is intended to help protect the 
compressor from short cycling. Some newer compressors 
already have a time delay built in and do not require this 
feature. Your compressor manufacturer can tell you if the 
lockout feature is already present in their system. When the 
thermostat compressor time delay occurs, it will fl ash the 
setpoint for up to fi ve minutes.
7)  Select Backlight Display - The display backlight improves 
display contrast in low lighting conditions. When the “C” 
terminal is connected, selecting backlight CdL On will keep the 
light on continuously. Select backlight OFF will turn the light on 
momentarily when any key is pressed. When the “C” terminal 
is not connected, regardless of the backlight selection, the 
light will be on momentarily when any key is pressed.
8)  Select Temperature Display Adjustment 4 LO to 4 HI - 
Allows you to adjust the room temperature display up to 4° 
higher or lower. Your thermostat was accurately calibrated 
at the factory but you have the option to change the display 
temperature to match your previous thermostat. The 
current or adjusted room temperature will be displayed on 
the display.
9)  Select °F or °C Readout - Changes the display readout to 
Celsius or Fahrenheit as required.
10) Select Fast Second Stage ON or OFF - (Heat Pump Only) 
In the RUN mode, with the Fast Heat feature enabled (FH 
Heat On), if the temperature is manually raised by 3°F (2°C) 
or more above the actual temperature using the 
, the 
second stage will energize immediately. With FH OFF, the 
thermostat will determine the optimum time (approximately 
0 to 30 minutes) to use Auxiliary/Second stage heat in 
addition to the Heat Pump.
11) 
Select Filter Replacement Reminder and Set Run 
Time  
Select the “Change Filter” reminder On or OFF. If 
selected On, press RUN/HOLD to select the time period 
from 25 to 1975 hours in 25 hour increments. In a typical 
application, 200 hours (default) of run time is approximately 
30 days. After the selected time of blower operation, the 
thermostat will display “Change Filter” as a reminder to 
change or clean your air fi lter. When “Change Filter” is 
displayed, press the RUN/HOLD button to clear the display 
and restart the time to the next fi lter change. A selection of 
OFF will cancel this feature.
12) Select  RUN/HOLD - Exit Menu.
INSTALLER/CONFIGURATION MENU 
To prevent compressor and/or property damage, if the 
outdoor temperature is below 50
o
F, DO NOT operate 
the cooling system.
CAUTION
!
OPERATION 
CHECK THERMOSTAT  OPERATION
If at any time during testing your system does not operate 
properly, contact a qualifi ed service person.
Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to 
Heating System.
1.  Move fan switch to ON position. The blower should begin to 
operate.
2.  Move fan switch to AUTO position. The blower should stop 
immediately.
Heating System
1.  Move SYSTEM switch to HEAT position. If the auxiliary 
heating system has a standing pilot, be sure to light it.
2. Press 
 to adjust thermostat setting to 1° above room 
temperature. The Heat Pump system should begin to 
operate. However, if the setpoint temperature is fl ashing, the 
compressor lockout feature is operating (see Confi guration 
menu, item 6).
3.  Adjust temperature setting to 4
o
 above room temperature. 
The auxiliary heat system should begin to operate and the 
Flame icon will be fl ashing.
4. Press 
 to adjust temperature setting below room 
temperature. The heating system should stop operating.