GE RV60 LED System Installation Guide

Page of 8
3
2
Prepare for Installation of
End LED Lights
For 48-inch LED Lights: 
46 1/4" (1175mm)
For 60-inch LED Lights: 
58 3/32" (1476mm) 
For 67-inch LED Lights:
65 15/32" (1663mm)
Right End Shield
LED Driver Leads
3/8" (10 mm)
Center punch
at intersection
and drill a
7/64-inch (2.8 mm)
hole
2 1/8" (54 mm)
Left End Shield
1-3/32" (28 mm)
1-3/32" (28 mm)
3/8" (10 mm)
End Mullion-Left
End Mullion-Right
View from inside case looking out
•  Measure 1 3/32-inches (28 mm) from the edge of the mullion 
nearest the door, and mark a vertical line near the top and 
bottom of the frame mullion.
•  Prepare for the upper end of the End LED Light. Mark a 
horizontal line a minimum 2 1/8-inches (54 mm) from the top 
of the door opening, and another horizontal line 3/8-inches 
(10 mm) below this line.
•  Prepare for the lower end of the End LED Light. 
  —  For 48-inch LED Lights mark a horizontal line 
  46 1/4" (1175mm) beneath the first line drawn for 
    the top Mounting Tab.
  —  For 60-inch LED Lights mark a horizontal line 
  58 3/32" (1476mm) beneath the first line drawn for 
      the top Mounting Tab.
  —  For 67-inch LED Lights, mark a horizontal line 
  65 15/32" (1663mm) beneath the first line drawn for 
    the top Mounting Tab.
  Then mark another line 3/8-inches (10 mm) below this line.
•  Center the center punch directly at the intersection of the 
horizontal lines and the vertical line (top and bottom) and 
establish a dimple.
•  Use power drill and 7/64-inch (2.8 mm) drill bit to drill 
holes at the intersection of the vertical center line and the 
horizontal lines.
•  Repeat these steps for the mullion on the other end of the case.
WARNING/AVERTISSEMENT
Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for 
enclosed wiring and components. / Risque de feu ou électrocution. Les pièces et câbles électriques risquent d’être endommagés lors du perçage 
des trous pour l’installation du luminaire à DEL.  Veuillez vérifier si des câbles et composantes se trouvent derrière la paroi avant de percer.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. / Pour éviter l'endommagement de 
câblage ou l'abrasion, ne pas exposer le câblage aux bords de feuilles de métal ou d'autres objets tranchants.