Cooling Module LEDs
Each cooling module has two (2) red LEDs on the back. Each LED corresponds to a single fan 
in the cooling module. (See Figure 4.7) When the LED is on, it indicates the fan has failed. 
When the LED is off, it indicates the fan is functioning properly.
Fig. 4.7
Cooling Module LEDs and Cooling Fan Locations
The RAID subsystem has a novel approach to stabilizing the temperature within the subsys-
tem: When the intelligent sensors on the backplane detect higher temperature, such as high 
ambient temperature or the failure of any cooling or PSU module, the system will turn the 
cooling fans to high speed to extract more heat. Once the ambient temperature cools down to 
normal or the cooling or PSU modules have been replaced, the cooling fans will return to low 
speed.
Color
Status
FLASHING Green
The power supply has not been turned on. The PSU module 
LED will blink when the subsystem is connected to a power 
source but not yet turned on.
Static Green
The PSU is operating normally and experiencing no problem.
Static Red
The PSU has failed and is unable to provide power to the sub-
system.
OFF
The PSU is not turned on. The PSU module LED will remain off 
even if the power cable has been plugged in but the power 
switch is not turned on.
Table 4.6