Siemens TV Converter Box 611 User Manual

Page of 324
Motor assembly 
 
6.1 Motor assembly 
 
WARNING 
 
The machine construction must be designed in such a way that both the rotor and the stator 
are each secured on one side only. See "Installation examples". If they are secured on both 
sides, this can result in significant material deformation in the machine construction due to 
thermal expansion, which could destroy the motor. 
 
 
 
DANGER 
 
Defective connecting cables can cause an electric shock and/or material damage (e.g. by 
fire). 
When installing the motor, make sure that the connection cables... 
 
are not damaged 
 
are not under tension 
 
cannot come into contact with any rotating parts 
Note the permissible bending radii (see "Interfaces"). 
The motor must not be held or pulled by the cables. 
 
 
 
DANGER 
 
Electrical shock hazard! When an installed torque motor rotates, potentially dangerous 
voltages are induced at the cable ends of the motor. 
Insulate terminals and leads in open cable ends or take measures to prevent torque motors 
that have been installed from rotating. 
There is also a risk of compression. 
 
 
 
WARNING 
 
Sharp edges can cause cuts and falling objects can injure feet. 
Always wear work gloves and safety shoes. 
 
 
1FW6 Built-in torque motors 
82
 
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7