Klark Teknik DN9340E User Manual

Page of 65
 
HELIX DN9340E/DN9344E Remote Control Software
 
User Guide 
 
 
 
17 of 65 
  
 
To Bypass the parametric EQ on the current channel 
 
Tick the †Bypass check box in the upper Parametric tab. 
 
To add a PEQ section to the graph 
Click on the Add button in the lower Parametric tab.  A PEQ 
panel with Level, frequency and Q is added to the tab (shown 
right) and a target appears on the graph at 1kHz. 
Left click on the target and drag it to the required frequency and 
dB level.  Right click on the target and drag the mouse up/down 
(the target remains still) to increase/decrease the width of the 
PEQ section, that is, by adjusting the Q value.  The values in the 
PEQ panel track the target. 
If required, fine tune settings by scrolling the PEQ panel FrequencyLevel and fields. 
 
Adjusting PEQ positions: The target provides quick but coarse adjustment, the scrolls enable 
fine adjustment.  If you know the exact values you wish to apply, it may be quicker to type the 
values into the PEQ panel.  Frequencies in kHz should be entered with a ‘k’ suffix, that is, 12.5k 
for 12.5 kHz.  Frequencies will be automatically adjusted to the nearest valid increment. 
 
To activate the target at an existing PEQ section 
 
Click anywhere on its PEQ panel, but note that if you click on the very bottom of the panel, 
you also click the Out field and thus change the in/out status.  The selected panel becomes 
highlighted and the target ‘switches’ to the associated PEQ section. 
The target cannot be ‘switched’ to another PEQ by clicking on the graphic (this would conflict with its 
function as a repositioning control for the underlying PEQ section). 
Note
 
The order of the PEQ panels will not necessarily mirror the order of the PEQ sections on the 
graph, as targets can be moved along the frequency axis to suit requirements. 
 
To switch a PEQ section out of the circuit 
 
Tick on the † Out check box at the bottom of the respective PEQ 
panel. 
 
The PEQ section is faded to grey on the graph and its contribution 
is removed from the overall frequency response.  The target 
stays on the PEQ section so that the PEQ can still be adjusted 
while switched out. 
To switch the PEQ section in again, clear the † Out check box. 
 
 
 
 
To remove a PEQ section from the graph 
Move the target to the PEQ section you wish to remove by clicking on its PEQ panel.  Click 
the Remove button in the Parametric Shaping tab. 
At the prompt, click Yes to confirm the removal the PEQ or No to cancel. 
The PEQ section is removed and the remaining PEQ panels re-numbered, if required. 
Hint 
PEQ In 