Klark Teknik DN9340E User Manual

Page of 65
 
HELIX DN9340E/DN9344E Remote Control Software
 
User Guide 
 
 
 
19 of 65 
  
 
To Bypass the Dynamic EQ on the current channel 
 
Tick the †Bypass check box in the upper Dynamic tab by clicking on it. 
 
To shape a Dynamic EQ section 
Click on its control panel in the lower Dynamic tab so that it is highlighted.  (Dynamics 
initially default to 1kHz). 
Scroll or type in the Lo Threshold (quiet) and the 
Hi Threshold (loud) for the signal level. 
Left click on the target and drag it to the 
required frequency and boost/cut.  The 
currently selected threshold is marked at the 
bottom left of the target.  The values in the 
Dynamic control panel track the target. 
Using the double-headed arrow to the top right 
of the target, toggle to the other threshold. 
Left click on the target and drag it to the 
required frequency and boost/cut. 
Right click on the target and drag the mouse up/down (the target 
remains still) to increase (narrow) or decrease (widen) the Q factor or 
choose a shelf response from the EQ slope  drop down menu in the 
Dynamic control panel. 
 
Note
 
The Q field is disabled when an EQ slope is selected; reset the EQ 
slope to Off to enable the Q field. 
 
If required, fine tune the settings at the PEQ panel by scrolling the FrequencyLevel and 
fields. 
Specify the response to sudden rises in dB level by setting an Attack time between 20 µs 
and 100 ms using the scroll to increment in allowable steps for the sample rate or by typing 
in a value (use u for µ).  Typed in values are automatically adjusted to the nearest 
allowable value. 
Specify the response to sudden drops in dB level by setting a Release time between 10 and 
2000 µs, using the scroll to increment in steps of 10 µs or by typing in a value. 
 
 
Adjusting the Dynamics: The target provides coarse visual adjustment, the scrolls enable fine 
tuning.  If you know the exact values you wish to apply to, it may be quicker to type the values 
into the Dynamic panel.  Frequencies in kHz should be entered with a ‘k’ suffix, that is, 12.5k 
for 12.5 kHz.  Frequencies will be automatically adjusted to the nearest valid increment. 
 
To activate the target on the other Dynamic 
 
Click anywhere on its Dynamic panel.  The selected panel becomes highlighted and the 
target cursor switches to the associated Dynamic, on the same threshold as your last edit. 
Hint 
Click the arrow to 
switch between 
high (HI) and low 
(LO) thresholds