5.3 Dynamic 
Equalisation 
 
To switch to the Dynamic Equalisation view 
 
Click on the Dynamic button of the Channel A or B Navigation Strip, as required.  (If staying 
on the same Channel you may prefer to click on a Dynamic tab). 
 
 
 
 
 
The upper Dynamic Mode tab is used to set the characteristic of the Threshold Dependent Dynamic EQ 
(   T-DEQ), bypass state and graph display mode (when a DN9340) for the current channel.  The lower 
Dynamic Shaping tab provides a control panel for each of the two Dynamic EQ sections that can be 
applied to the frequency response.  The Dynamic EQ sections can also be adjusted at the display by 
using the target cursor. 
 
To set the Dynamic EQ mode for the channel 
Select a Proportional, Constant or Symmetrical Q 
characteristic from the EQ Type  drop down 
menu. 
Use the Unit Display   drop down menu to set the 
Dynamic EQ display mode that DN9340 units 
should assume when taken out of slave 
operation; this only comes into effect if the slave 
is a DN9430.  The choice made here has no 
effect on your AddIn device display. 
 
Note
 
Refer to the DN9340/DN9344 Operators Manual for application notes on Equalisation modes 
and Q. 
The black graph
shows overall
response.  The
red graph shows
the response of
the selected LO
or HI Dynamic
The Dynamic 
section’s freq, 
level and Q are 
adjusted by 
dragging the 
‘target’ or  
setting values 
Dynamic Mode 
tab 
For a shelf 
dynamic, choose 
an EQ slope 
Tick the check box to switch the
PEQ section out of the circuit