DMP Electronics Inc. Network Router LT-0424 User Manual

Page of 4
 3.      
CHANGE RARP DISABLED
Connect the ETHER-COM to an Ethernet network after entering the command in line number 3. It should be connected
to the actual network at the location where the ETHER-COM will be permanently installed.
 4.      
INIT 451
The ETHER-COM initialization will begin 5 seconds after pressing the Return key. If the ETHER-COM has been
properly attached to a network and no other self-diagnostic errors are encountered, the ETHER-COM will restart.
The following messages should then be displayed:
DMP, Inc. ETHER-COM Initialization.....
Ethernet Address:   00-80-a3-0f-4a-d4            Internet Address: (Undefined)
Flash Rom Version   2.0 (May 12, 1998)
Flash Version:          3.5/1   (970707)
Current Diagnostics report:
      NVR Config:              Normal                   Ram Size:        256 KB
      CPU Speed:               10 MHz                    Gate Array:      Rev 2
      Flash Version:          3.5/1 (970707)       Ethernet: UTP
      Errors:                      None
Skipping DHCP.
Skipping BOOTP.
Skipping RARP.
Checking 2 sections from flash:
       From address 0x20004 to 0x20018,   281414 Bytes) -> not copied.
       From address 0x64b5e to 0x210000,      7712 Bytes) -> copied.
Load Complete - Boot in Progress
Press the Return key to display the username> prompt. Enter your name, followed by the Return key to display the
Local1> prompt.
Before any configuration changes can be made, you must become the privileged user. To do this, type SET PRIV
followed by the Return key. The display will then change to password> . Type 
SYSTEM  , then press the Return key.
This changes the ETHER-COM to the Local>> prompt.
Enter the following commands at the Local>> prompt:
1.
CHANGE IPADDRESS xxx.xxx.xxx.xxx (where xxx... is the IP address for the unit. Note: This address
must be unique to the network).
2.
CHANGE GATEWAY xxx.xxx.xxx.xxx (where xxx... is the IP address for the Gateway or router attached to
this LAN segment).
3.
CHANGE SUBNET MASK xxx.xxx.xxx.xxx (where xxx... is the subnet mask provided by the network
administrator)
4.
CHANGE SPEED xxx (where xxx is the baud rate configured on the 462N (300 to 9600 baud)).
2841 E. Industrial Drive  Springfield, MO  65802-6310  800-641-4282
Ether-Com Programming