DMP Electronics Inc. Network Router LT-0424 User Manual

Page of 4
5.
CHANGE FLOW CONTROL NONE
6.
CHANGE DEDICATED TCP xxx.xxx.xxx.xxx:2001U (where xxx... is the IP address of the Ether-Com
TM
connected to the SCS-1 Receiver or PC running Remote Access+
TM
).
7.
CHANGE AUTOSTART ENABLED
8.
SHOW SERVER - Check and confirm the unit’s IP address, Subnet Mask  and the Gateway address.
10.
SHOW PORT - Check and confirm the speed, flow control, dedicated service, and autostart options are
set correctly. (The unit is now ready to be connected to the 462N/862N with the cable provided with the
ETHER-COM.)
11.
LOGOUT
Important Note
Once the ETHER-COM has been configured in this manner, no local access is allowed through the serial port
while the unit is connected to the network. To reconfigure the Ether-Com you must remove power from the unit,
disconnect it from the network, and then reapply power. Press the Enter key within 10 seconds to enter the
configuration mode. Enter the command FLUSH NVR to return the unit to its factory defaults. This erases all
options including the IP address.
SCS-1 Receiver
The unit that connects to the SCS-1 Receiver is configured in the same manner with the exception of Dedicated
Service.
The CHANGE DEDICATED option will not include any IP address, CHANGE DEDICATED TCP :2001U. This is
necessary because the unit connected to the receiver will need to communicate with many different IP addresses.
Configuration for use with Remote Access+™ on a PC
This configuration is for applications where the Ether-Com server is used as the ethernet network interface for an
IBM compatible PC on which is installed the DMP Remote Access™ software. The Remote Access program is
used as a monitoring automation system and should be configured for HST Monitoring to allow it to process
incoming alarm and system information from DMP panels installed on the same network.
HST Monitoring
The unit that connects to your PC running Remtoe Access+
TM
 is  configured in the same manner with the exception
of Dedicated Service.
The CHANGE DEDICATED option will not include any IP address, CHANGE DEDICATED TCP :2001U. This is
necessary because the unit connected to the receiver will need to communicate with many different IP addresses.
2841 E. Industrial Drive  Springfield, MO  65802-6310  800-641-4282
Ether-Com Programming