ELECTRIC DRYER ELECTRICAL CONNECTIONS 
(FOR U.S.A. ONLY)
Power Cord 
4-wire receptacle (NEMA Type 14-30R) 
3-wire receptacle (NEMA Type 10-30R) 
Connection Options
Direct Wire
4-wire direct 
3-wire direct
     1"
(25 mm)
       5"
(127 mm)
Standard Power Supply Cord Connectors
 
Flanged Spade Connector 
Ring Connector
Connecting Neutral Ground and Neutral Wires
1. 
 Remove center terminal block screw (A) and the neutral  
ground wire (B) by removing the green external ground 
conductor screw (C).
2.  Connect neutral ground wire (B) and neutral wire (white or 
center wire) (D) of power supply cord under center terminal 
block screw (A). Tighten screw.
Connecting 4-Wire Connection: Power Supply Cord
IMPORTANT: A 4-wire connection is required for mobile 
homes and where local codes do not permit the use of 3-wire 
connections.
Connecting Power Cord Ground Wire
3. 
 Connect ground wire (green or bare) (E) of power supply cord 
under green external ground conductor screw (C). Tighten 
screw.
Connecting Remaining Wires
4. 
 Connect remaining wires under outer terminal block screws 
(F). Tighten screws. Finally, reinstall terminal block cover to 
dryer rear panel. Secure cover with hold-down screw.
A
C
B
A
B
D
C
E
F