Serial Audio Interface
Serial Audio Interface Programming Model
 
MOTOROLA
DSP56012 User’s Manual 
6-15
6.3.2.11
RCS Receiver Interrupt Enable (RXIE)—Bit 11
When the read/write Receiver Interrupt Enable (RXIE) control bit is set, receiver 
interrupts for both left and right data words are enabled, and the DSP is interrupted 
if either the RLDF or RRDF status bit is set. When RXIE is cleared, receiver interrupts 
are disabled, however, RLDF and RRDF bits still indicate the receive data register full 
conditions and can be polled for status. Note that clearing RXIE will mask a pending 
receiver interrupt only after a one-instruction-cycle delay. If RXIE is cleared in a long 
interrupt service routine, it is recommended that at least one other instruction should 
be inserted between the instruction that clears RXIE and the RTI instruction at the 
end of the interrupt service routine. 
There are three different receive data interrupts that have separate interrupt vectors:
1. Left Channel Receive interrupt is generated when RXIE = 1, RLDF = 1, and 
RRDF = 0.
2. Right Channel Receive interrupt is generated when RXIE = 1, RLDF = 0, and 
RRDF = 1.
3. Receive interrupt with exception (overrun) is generated when RXIE = 1, 
RLDF = 1, and RRDF = 1. This means that the previous data in the receive data 
register was lost and an overrun occurred.
To clear RLDF or RRDF during Left or Right channel interrupt service, the receive 
data registers of the enabled receivers must be read. Clearing RLDF or RRDF will 
clear the respective interrupt request. If the “Receive interrupt with exception” 
indication is signaled (RLDF = RRDF = 1), then RLDF and RRDF are both cleared by 
reading the RCS register, followed by reading the receive data register of the enabled 
receivers.
Note:
Receivers 0 and 1 share the same controller. This means that the enabled 
receivers will be operating in parallel and any interrupt signaled will indicate 
a condition on all enabled receive data registers. The RXIE bit is cleared 
during hardware reset and software reset.
6.3.2.12
RCS Receiver Interrupt Location (RXIL)—Bit 12
The read/write Receiver Interrupt Location (RXIL) control bit determines the 
location of the receiver interrupt vectors. When RXIL = 0, the Left Channel Receiver, 
the Right Channel Receiver and the Receiver Exception interrupt vectors are located 
in program addresses $16, $18, and $1A, respectively. When RXIL = 1, the Left 
Channel Receiver, the Right Channel Receiver and the Receiver Exception interrupt 
vectors are located in program addresses $46, $48, and $4A, respectively. The RXIL 
bit is cleared during hardware reset and software reset. Refer to Table 6-1 
on page 6-9.