Furuno 1834C-BB User Manual

Page of 86
 
2-4
2.2  Wiring the Power Supply Unit 
(MODEL 1954C-BB/1964C-BB) 
2.2.1  Power supply unit PSU-005 (MODEL 1954C-BB) 
1.  Unfasten three M4 screws to remove the cable clamp. 
2.  Unfasten six M4 screws to remove the cover. 
3.  Attach the VL connector of the power supply cable VL3P-VV-S2X2C-AA050 (supplied as 
installation materials) to J1 on the POWER Board.   
4.  Attach the VH and NH connectors of MJ-B24LPF0009-050 cable (supplied as 
installation materials) to these locations: VH9, J3; VH4, J4, NH13, J5. 
VL-3
VL3P-VV-S2X
2C-AA050
cable
(to 12-24 VDC)
MJ-B24 
LPF0009-050
 cable
(to processor
 unit)
Slot
(large)
Slot
(small)
POWER Board
19P1006
ANT (J8)
Signal cable
(to antenna unit)
J1
Ground 
terminal
(Wing bolt)
V
H
9
N
H
13
V
H
4
J3
J4
J5
Shield
Cable tie
(if necessary)
 
Power supply unit, cover removed 
 
5.  Lay two cables on the slots referring to the figure above. 
To prevent strain to the cable MJ-B24LPF0009-050, fasten a cable tie (local supply) at the 
position shown above. 
6.  Reattach the cover (removed at step 2). 
7.  Reattach the cable clamp. 
8.  Connect the antenna cable to the ANT port on the power supply unit. 
9.  Connect a ground wire (local supply, IV-2sq) between the ground terminal and ship’s 
ground.