Jenn-Air W10526003A User Manual

Page of 28
5
Make sure there is a minimum of 18" (45.7 cm) of straight 
vent between the elbows if more than one elbow is used.
Elbows too close together can cause excess turbulence that 
reduces airflow.
Do not use a 5" (12.7 cm) elbow in a 6" (15.2 cm) or 3
¹⁄₄" x 10" 
(8.3 x 25.4 cm) system.
Do not reduce to a 5" (12.7 cm) system after using 
6" (15.2 cm) or 3
¹⁄₄" x 10" (8.3 x 25.4 cm) fittings.
Avoid forming handmade crimps. Handmade crimps may 
restrict airflow.
Use a Jenn-Air
®
 vent cap for proper performance. If an 
alternate wall or roof cap is used, be certain the cap size is 
not reduced and that it has a backdraft damper.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the 
cap.
The length of vent system and number of elbows should be kept 
to a minimum to provide efficient performance.
The maximum equivalent length of the vent system is 60 ft 
(18.3 m). For altitudes above 4,500 ft (1272 m), reduce 
recommended vent run by 20% for best performance.
Cold Weather Installations
An additional backdraft damper should be installed to minimize 
backward cold air flow and a thermal break installed to minimize 
conduction of outside temperatures as part of the vent system. 
The damper should be on the cold air side of the thermal break.
Makeup Air
Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of air 
movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.
Venting Methods
Common venting methods are shown for a counter-mounted 
downdraft cooktop. The cooktop may be vented through the wall 
or floor. 
Concrete Slab Installations - Exhaust Through Wall
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Option 1 - Roof Venting
Option 2 - Wall Venting
A. Roof cap
B. 6" (15.2 cm) round roof venting
A. 6" (15.2 cm) round wall venting
B. Wall cap
A
B
A
B
Option 3 - Venting Between 
Floor Joist
Option 4 - Venting behind 
Cabinet Kick Plate
A. Wall cap
B. 6" (15.2 cm) round wall venting
A. Wall cap
B. 6" (15.2 cm) round wall venting
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round metal vent
F. 6" (15.2 cm) round PVC coupling
G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 30 ft (9.1 m) max.
L. 6" (15.2 cm) round 90° PVC sewer pipe elbow
M. 6" (15.2 cm) round PVC coupling
N. 12" (30.5 cm) minimum
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft
(0.8 m) 
90° elbow
5.0 ft
(1.5 m)
6" (15.2 cm) 
wall cap
0.0 ft
(0.0 m)
A
B
A
B
 
 
 
 
 
 
A
B
C
D
E
F
G
H
I
J
L
K