Jenn-Air W10526003A User Manual

Page of 28
6
Example vent system
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that 
will not operate if plugged into an outlet that is not properly 
polarized.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 
The wiring diagrams are provided with this cooktop. See 
“Wiring Diagrams” on a separate sheet. The wiring diagrams 
are located on the left underside of the cooktop base.
Gas Supply Requirements
Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 
IMPORTANT: Leak testing of the cooktop must be conducted 
according to the manufacturer’s instructions.
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm) 
to 6" (15.2 cm) transition
4.5 ft
(1.4 m)
6" (15.2 cm) to 3
¹⁄₄" x 10" 
(8.3 cm x 25.4 cm) transition
1 ft
(0.3 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm) 
to 6" (15.2 cm) 90° elbow 
transition
5.0 ft
(1.5 m)
6" (15.2 cm) to 3
¹⁄₄" x 10" 
(8.3 cm x 25.4 cm) 90° elbow 
transition
5.0 ft
(1.5 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm) 
90° elbow
5.0 ft
(1.5 m) 
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm) 
flat elbow
12.0 ft
(3.7 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm) 
wall cap
0.0 ft
(0.0 m)
1- 90° elbow
= 5 ft (1.5 m)
8 ft (2.4 m) straight
= 8 ft (2.4 m)
1 - wall cap
= 0 ft (0 m)
System length
= 13 ft (3.9 m)
90˚ elbow
2 ft 
(0.6 m)
6 ft (1.8 m)
wall cap
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.