Output Voltage Sensing 
26 
Series N5700 User’s Guide  
•  Loosen the two chassis screws marked A halfway. 
•  Assemble the protective shield to the chassis and tighten the 
two screws to fix the shield to the chassis. Screws tightening 
torque: 4.8-5.3 in-lb 
•  Tighten the wires to one of the shield sides using tie-wrap or 
equivalent. Refer to the following figure. 
•  Ensure that the wire length inside the shield is long enough 
to provide proper strain relief. 
Output Voltage Sensing 
WARNING 
SHOCK HAZARD  There is a potential shock hazard at the sense connector 
when using a power supply with a rated output greater than 40V. Ensure that 
the local sense and remote sense wiring insulation rating is greater than or 
equal to the maximum output voltage of the power supply. Ensure that the 
connections at the load end are shielded to prevent accidental contact with 
hazardous voltages. 
Local and remote sense connections are made at the J2 connector. 
The connector has a removable plug that makes it easy for you to 
make your wire connections. Refer to the following figure for the 
terminal assignments. 
A
A
Load
wires
1  Remote sense (+)
2  Local sense (+)
3  Not connected
4  Local sense (-)
5  Remote sense (-)