Serial Upgrade Method
TXD and RXD should be green.  They will flash if Enter is 
pressed.
Figure C-2.  Flash Loader Status Lights, Normal Condition
c.  Press Enter a few times to display the system prompt “#” on screen.
d.  If the prompt does not appear, continue with step 10 (troubleshooting).
e.  If the prompt appears, continue with step 11 (uploading files).
10.  To troubleshoot the serial connection:
a.  If the DCD and CTS status lights are green, re-check the communication 
settings in the loader, and verify that the COM port and Baud Rate 
settings are correct.
b.  To verify PresentationPRO-II communication settings, on the front panel 
of the PresentationPRO-II unit press {
HOME> {SYSTEM> 
{
CONSOLE} to display the Console Port Setup Menu.
Figure C-3.  Console Port Setup Menu  (sample)
c.  On the menu, ensure that the following settings are selected:
Baud Rate = 115200
Data Bits = 8
Parity = NONE
Stop Bits = 1
d.  Repeat steps 7 and 8 above, then re-check the status lights.  
e.  With communication status OK, continue with step 11.
11.  To upload files to the PresentationPRO-II unit, click the "Open script file to read 
and upload" button.
12.  In the dialog, select "Upload_All.sld" and click Open.  The PresentationPRO-II 
unit should immediately display the "
System in LOADER MODE" message.