timeserver set
<daytime> <ip>
[nosync]
Sets the time service protocol,
time server’s IP address and the
device’s time zone.
time server’s IP address and the
device’s time zone.
H/H
timeserver set
<time|ntp> <ip>
<utc[<+|-
>0100~1200]>
[nosync]
Sets the time service protocol,
time server’s IP address and the
device’s time zone.
time server’s IP address and the
device’s time zone.
H/H
timeserver sync
Retrieves the date and time from
the time server.
the time server.
H/H
log show
Displays the device’s logs.
M/L
log clear
Clears the device’s logs.
H/H
wdog show
Displays the current watchdog
firmware protection feature status
and timer.
firmware protection feature status
and timer.
H/~
wdog set
<msec|0:disable>
Sets the watchdog count. 0 turns
the watchdog off.
the watchdog off.
H/~
monitor show
Displays the hardware monitor’s
statistics.
statistics.
L/L
monitor enable
Turns the hardware monitor on.
H/H
monitor disable
Turns the hardware monitor off.
H/H
monitor vlimit
<idx> <high> <low>
Sets the maximum (<high>) or
minimum (<low>) voltage at the
specified voltage sensor. You can
specify a voltage with up to three
digits after a decimal point (0.941
for example).
Normal voltage at each sensor:
Idx: 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
minimum (<low>) voltage at the
specified voltage sensor. You can
specify a voltage with up to three
digits after a decimal point (0.941
for example).
Normal voltage at each sensor:
Idx: 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
H/H
monitor tlimit
<idx> <high> <low>
Sets the maximum (<high>) or
minimum (<low>) temperature at
the specified temperature sensor.
You can specify a temperature
with up to three digits after a
decimal point (-50.025 for
example).
Temperature sensor locations:
Idx: 1=DSL, 2=CPU, 3=HW
monitor
minimum (<low>) temperature at
the specified temperature sensor.
You can specify a temperature
with up to three digits after a
decimal point (-50.025 for
example).
Temperature sensor locations:
Idx: 1=DSL, 2=CPU, 3=HW
monitor
H/H
user online
Displays online user info.
M/~
user enable
<name>
Turns on the specified user name
of multi-login.
of multi-login.
H/H
user disable
<name>
Turns off the specified user name
of multi-login.
of multi-login.
H/H
user set
<username>
<password>
<high|middle|low>
Creates or edits the password and
privilege level of the specified
user name.
privilege level of the specified
user name.
H/H
user delete
<name>
Removes the specified user name
of multi-login.
of multi-login.
H/H
Table 88 Commands (continued)
CLASS
COMMAND
PARAMETERS
DESCRIPTION
P