Bosch d9412gv3 User Manual

Page of 76
D9412GV3/D7412GV3 | Operation and Installation Guide | 9.0  
Off-Board Points 
 
Bosch Security Systems, Inc. | 10/10 | F01U143070-03 
41
 
9.3.4  Wiring Data Expansion Loops to POPEX 
Modules 
Each POPEX Module has two positive (+) and two 
negative (-) data expansion loop terminals. Up to 119 
POPITs can be connected to one D8125 on the 
D9412GV3; up to 67 POPITs for the D7412GV3 
(Figure 16 on page 38 and Figure 17 on page 39). 
To connect the data expansion loops to the D8125 
POPEX Module: 
1.  Connect the positive (+) data terminal from the 
first POPIT on the data expansion loop to one of 
the D8125’s positive (+) terminals. 
2.  Connect the negative (-) data terminal from the 
first POPIT on the data expansion loop to one of 
the D8125’s negative (-) terminals. 
9.3.5  POPIT Sensor Loops 
The number of normally-open and normally-closed 
detection devices each sensor loop can supervise is 
limited only by the resistance on the loop. Resistance 
on each sensor loop must be less than 100 
, not 
including the EOL resistor. 
 
Certain UL and NFPA applications can 
limit the number of detection devices. 
Consult the appropriate UL or NFPA 
standards. 
POPITs detect open, shorted, normal, and grounded 
circuit conditions on their sensor loops. They send the 
condition of their loops to the control panel. A ground 
on the sensor loop sends a general system ground-
fault condition report. Each POPIT is programmed 
and sends signals to the control panel separately.  
Terminate each POPIT sensor loop with the 33 k
 
end-of-line (EOL) resistor (D106F) included with each 
POPIT. 
Use a twisted-pair wire (six twists per foot) in all 
POPEX and POPIT installations for the data 
expansion loop wiring and the POPIT sensor loops. 
Run wires away from AC sources to prevent AC 
induction. If you suspect a noisy environment, use 
shielded cable. Refer to Section 9.3 Installing the 
D8125 POPEX Module 
on page 39. 
9.3.6  POPIT Module Point Assignments 
Six switches on each POPIT assign the module to a 
point number. For POPIT switch settings, refer to 
Point Assignment in the D9412GV3/D7412GV3 
Program Record Sheet
 (P/N: F01U170809). The 
program record sheet provides information about the 
Point Assignments tables. Figure 18 on page 42 is an 
example of the tables. 
 
9.3.7  Program Record Sheet 
The first column of the table in Figure 18 on page 42 
contains the POPIT Switch Settings for the D9127 
POPITs. On the D9127T/U POPIT, switches are 
numbered 0 to 6, from left to right. Set the indicated 
switches to the ON position. If a dash (
) appears in 
the switch position, set the switch to the OFF position. 
The second column contains the Translation of the 
point number into the Zonex format. Refer to Point 
User Flag
 in the D9412GV3/D7412GV3 Program 
Entry Guide
 (P/N: F01U170807) for an explanation of 
this feature. 
The third column contains the Point Number as 
shown at keypads.  
The fourth column contains the Point Index. Refer to 
Point Index Parameters in the D9412GV3/D7412GV3 
Program Entry Guide
 (P/N: F01U170807) for an 
explanation of the point index. 
The fifth column, Area Assign, shows the area to 
which the point is assigned.  
The sixth column shows the Debounce Count for the 
point. Refer to Debounce Count in the 
D9412GV3/D7412GV3 Program Entry Guide  
(P/N: F01U170807). 
The seventh column shows the BFSK/Relay report 
code, which associates a relay to an individual point.  
The eighth column contains the Custom Point Text 
displayed at keypads for the point. The text is sent to 
the receiver when the control panel uses the Modem 
IIIa
2
 format.