Panasonic Section 520 User Manual

Page of 54
Section 520 - TSAPI
Chapter 3. Installation
DBS-92-520
Issued April 2000
  13
Panadrvr and call cleared events sent to all the applications monitoring 
the affected extensions. Note, this has not effect on the actual DBS call.
Option: c=
Range: N/A
Default: None
Runtime modifiable: N/A
Purpose: Specifies a load time ASCII text configuration file containing 
the aforementioned options. The name and full path of the file must be 
specified.
The format of the file is as follows:
api=1
port=2
/this is a comment
baud=19200
...
Comments must begin at a new line. Options specified on the command 
line following this option override any options contained in this config 
file.
Option: filters=
Range: 0 or 1
Default: 0
Runtime modifiable: Yes
Purpose: Enables (1) or disables (0) Panadrvr’s recognition of an 
application’s monitor filter settings. By default, the driver ignores any 
application set filters. This setting does not effect the 
CSTAChangeMonitorFilter requests.