Kathrein 9986492 User Manual

Page of 116
Return Path IF Menu 
 
51
Carrying out measurements  
By pressing this button, the MSK 33 is set to analogue reception and measures the 
following values:  
- Audio carrier spacing from TT1 (sc1) and TT2 (sc2) 
- Nicam audio carrier spacing (if available)  
- Nicam bit error rate  (BER) 
- Minimal and maximal level (min./max.) 
Level measurement ANALOGUE 
The following displays appear on the screen, when the button, „measure,“ is 
pressed.  
Measurement of the audio carrier spacing  
 
Audio carrier 1: -13.5 dB 
Audio carrier  2: -19.5 dB 
 
 
Measurement of the Nicam audio carrier spacing and the bit error rate  
 
Nicam audio carrier spacing 1: - 18.5 dB 
Nicam audio carrier spacing: 5.6E-06 (5.6
-6
 
 
Measurement of the min./max. level 
In the display, the following values are represented:  
Minimal level: 77.5 dBµV 
Maximal level: 82.5 dBµV 
In this function, the MSK 33 measures the minimal and the 
maximal level, so the check points can be tracked for level 
fluctuations.  
As long as this measurement function is called up, the MSK 33 measures the 
minimal level and the maximal level. This measurement function serves for 
monitoring the check points for level fluctuations. 
 
Measurement of the current level 
In the display appears: 
Channel:  IF 
Frequency: 38.9 MHz 
Analogue reception: A 
Current level: 79.5 dBµV
 
 
An „A“ in front of the level display means, that the MSK 33 has been set to 
analogue level measurement. Even after exiting the menu, the MSK 33 stays 
set to ANALOGUE reception.  
 
For level measurement on digital IF signals, the MSK 33 can be switched-
over to the digital menu (refer to the respective section).  
Selecting the colour standards PAL, SECAM and NTSC 
(the lower softkey)  
 
 
----TV MEASURE ALL ---
SC1/SC2:-13.5/-19.5dB 
NICAM:  
-18.5 
dB 
BER  : 
 
5.6E-06