Avaya S8100 User Manual

Page of 408
1
Install and cable a G600 cabinet
Install off-premises station wiring
S8100 Installation and Upgrades
123
November 2003
Figure 40: Connections for one to eight out-of-building analog telephones
 on page 124 shows the connections for up to 24 
off-premises analog telephones, with concentrations of analog line pairs used at both buildings to 
minimize the off-premises wiring required. At the MDF, jumpers must be connected between 1 
row/connecting block in the white field and up to 3 rows/connecting blocks in the purple field. At the 
station location, a WP-90929, List 1 concentrator cable is used. There are 8 station appearances on each 
of the 3 fingers of the concentrator cable. See 
crdfobt RPY 012398
1
2
3
3
4
5
5
5
6
6
7
8
9
10
11
Figure notes
1
Locally engineered cables
2
Out-of-building wiring
3
Multipair protector units (primary 
protectors with heat coils or equivalent 
with sneak-current protection)
4
356A adapter
5
B25A cable
6
Out-of-building analog telephones
7
Part of MDF or patch panel
8
Station side (white field)
9
System side (purple field)
10
Cross-connect jumpers
11
To Analog Line circuit pack (TN2183, 
TN769, TN742, or TN746B)