1 Install and cable a G600 cabinet
Install off-premises station wiring
124
S8100 Installation and Upgrades
November 2003
Figure 41: Connections to 24 out-of-building telephones
Circuit protectors
Both building entrances require carbon block or equivalent protection and sneak-current protection. 
Provide this protection with a 4-type protector. The 4-type protector is equipped with a heat coil or a 3-
type protector plus a separate sneak-current protector.
The 4-type protector is the preferred device. For installations not using primary protection, always use 4-
type protectors. When the 3-type protector is already installed, a separate sneak-current protector is 
required. The multipair protector units and the off-premises cabling must be locally engineered. 
Connectorized multipair protector units (female 25-pair connector) are recommended. 
 on page 125 shows the recommended protectors.
crdf24o RPY 012398
1
2
2
3
4
5
5
5
6
7
7
7
7
7
7
8
9
10
11
12
Figure notes
1
Locally engineered cables
2
Multipair protector units (primary protectors with 
heat coils or equivalent with sneak-current 
protection)
3
B25A cable
4
Concentrator cable (WP90929 List 1)
5
356A adapter
6
Out-of-building wiring
7
Out-of-building analog telephones
8
Part of MDF or patch panel
9
Station side (white field)
10
System side (purple field)
11
Cross-connect jumpers
12
To TN2183, TN769, TN742, or 
TN746B Analog Line circuit pack