User ManualTable of ContentsAbout this Document1Product Summary1Tools Needed1Installation1General Sensor Installation Guidelines1Install on a Wall11. Determine a suitable location for the UFT.12. Mark where the magnet will be installed.13. Drill a 3/4” diameter hole 3/4” deep into the wall.14. Push the magnet into the hole, magnet side first.15. Remove the UFT cover by squeezing the cover ends firmly to release the tab on the cover from t...16. Remove the circuit board from the UFT base by pulling back the plastic tab and lifting the bat...17. Mark where the UFT will be installed over the magnet. See Figure 1 for acceptable magnet locat...1Figure 1. Acceptable magnet locations for a wall mounted UFT.18. Verify the UFT reed switch is properly aligned with the installed magnet.19. Mount the UFT base with screws or brads. Use spacers to compensate for metal surfaces or heigh...110. Reattach the circuit board to the UFT base211. Attach the External Switch (See “Connecting External Switch” in this manual)212. Reattach the UFT cover to the UFT base.2Install in an Electrical Box2Mounting the box on a wall21. Determine a suitable location for the UFT.22. Mark where the magnet will be installed.23. Drill a 3/4” diameter hole 3/4” deep into the stud or wall.24. Mark where the box will be installed over the magnet.25. Mark the box at the location where the magnet will enter the box.26. Drill a 13/16” hole in the box at the magnet location.27. Mark where the UFT will be installed on the box.28. Verify the UFT reed switch is properly aligned with the magnet hole.29. Mount the box using screws or brads making sure to align the hole in the box with the hole in ...210. Push the magnet, magnet side first, through the hole in the box and into the hole in the stud...211. Mount the UFT in the box using velcro strips.212. Remove the UFT cover by squeezing the cover ends firmly to release the tab on the cover from ...213. Attach the External Switch (See “Connecting External Switch” in this manual)214. Reattach the UFT cover to the UFT base.2Mounting the box in a wall21. Determine a suitable location for the UFT.22. Mark the box at the location where the magnet will be installed.23. Drill a 3/4” hole in the box at the magnet location.24. Insert the magnet into the hole.25. Mark where the UFT will be installed on the box26. Verify the UFT reed switch is properly aligned with the magnet.27. Mount the box in the wall using screws or brads.28. Mount the UFT in the box using velcro strips.29. Remove the UFT cover by squeezing the cover ends firmly to release the tab on the cover from t...210. Attach the External Switch (See “Connecting External Switch” in this manual)211. Reattach the UFT cover to the UFT base.2Connecting External Switch2Connection Guidelines2Making the Connection21. Make the connection to the external fire detection device. (See your device’s instructions.)22. Feed the wire through the hole in the bottom of the UFT.23. Attach the wire to the terminal block. See Figure 2.2Figure 2. UFT component locations.2Programming21. Set the panel to program mode.32. Proceed to the LEARN SENSORS menu.33. Select the appropriate zone type and zone number assignments.34. Set the external switch in the alarm condition (open for a normally closed circuit, closed for...35. Trip the sensors tamper switch by removing the sensor cover.36. Exit program mode.37. Place the cover back on the sensor.3Testing31. Set the panel to the installer zone test mode.32. Trip the sensor.33. The signal strength from the UFT will be displayed on all keypads. It should be 15 or higher f...3Specifications3FCC Notice4Size: 396 KBPages: 4Language: EnglishOpen manual