140 • Chapter 7 Application Programming
DMC-3425
Converting to User Units
Variables and arithmetic operations make it easy to input data in desired user units such as inches or
RPM.
RPM.
The DMC-3425 position parameters such as PR, PA and VP have units of quadrature counts. Speed
parameters such as SP, JG and VS have units of counts/sec. Acceleration parameters such as AC, DC,
VA and VD have units of counts/sec2. The controller interprets time in milliseconds.
parameters such as SP, JG and VS have units of counts/sec. Acceleration parameters such as AC, DC,
VA and VD have units of counts/sec2. The controller interprets time in milliseconds.
All input parameters must be converted into these units. For example, an operator can be prompted to
input a number in revolutions. A program could be used such that the input number is converted into
counts by multiplying it by the number of counts/revolution.
input a number in revolutions. A program could be used such that the input number is converted into
counts by multiplying it by the number of counts/revolution.
Instruction Interpretation
#RUN Label
IN "ENTER # OF REVOLUTIONS",N1
IN "ENTER # OF REVOLUTIONS",N1
Prompt for revs
PR N1*2000
Convert to counts
IN "ENTER SPEED IN RPM",S1
Prompt for RPMs
SP S1*2000/60
Convert to counts/sec
IN "ENTER ACCEL IN RAD/SEC2",A1
Prompt for ACCEL
AC A1*2000/(2*3.14)
Convert to counts/sec2
BG Begin
motion
EN End
program
Hardware I/O
Digital Outputs
The DMC-3425 has 3 uncommitted outputs. Each bit on the output port may be set and cleared with
the software instructions SB (Set Bit) and CB(Clear Bit), or OB (define output bit).
the software instructions SB (Set Bit) and CB(Clear Bit), or OB (define output bit).
Example- Set Bit and Clear Bit
Instruction Interpretation
SB3
Sets bit 3 of output port
CB2
Clears bit 2 of output port
Example- Output Bit
The Output Bit (OB) instruction is useful for setting or clearing outputs depending on the value of a
variable, array, input or expression. Any non-zero value results in a set bit.
variable, array, input or expression. Any non-zero value results in a set bit.
Instruction Interpretation
OB1, POS
Set Output 1 if the variable POS is non-zero. Clear Output 1 if
POS equals 0.
POS equals 0.
OB 2, @IN [1]
Set Output 2 if Input 1 is high. If Input 1 is low, clear Output 2.
OB 3, @IN [1]&@IN [2]
Set Output 3 only if Input 1 and Input 2 are high.
OB 3, COUNT [1]
Set Output 3 if element 1 in the array COUNT is non-zero.
The output port can be set by specifying an 8-bit word using the instruction OP (Output Port). This
instruction allows a single command to define the state of the output port, where 20 is output 1, 21 is
output 2 and so on. A 1 designates that the output is on.
instruction allows a single command to define the state of the output port, where 20 is output 1, 21 is
output 2 and so on. A 1 designates that the output is on.