178 • Appendices 
 
DMC-3425 
IN[x] (To controller)
TO CONTROLLER
RP3 / RP1 = 4.7K OHMS
ICM-1460
CONNECTIONS
IN[x]
OPTO-COMMON
RP2 / RP4 = 2.2K
VCC
 
Figure A-1 
Opto-isolated outputs: 
The signal “OUT[x]" below is one of the isolated digital outputs where x stands for the digital output 
terminals.   
The OPTO-COMMON needs to be connected to an isolated power supply.  The OUT[x] can be used to 
source current from the power supply.  The maximum sourcing current for the OUT[x] is 25 ma.  
Sinking configuration can also be specified.  Please contact Galil for details. 
The default state of the outputs may also be set through the resistor pack RP5.  With this resistor in it’s 
default state, the opto-isolator will be ON.  By reversing RP5 in its socket, the opto-isolator will be 
OFF by default. 
 
Figure A-2 
 
* Only available with ICM-1460