DMC-3425 
Appendices
  179 
64 Extended I/O of the DMC-3425 Controller   
 
The DMC-3425 controller offers 64 extended I/O points, which can be interfaced to Grayhill and 
OPTO-22 I/O mounting racks.  These I/O points can be configured as inputs or outputs in 8 bit 
increments through software.  The I/O points are accessed through two 50-pin IDC connectors, each 
with 32 I/O points. 
 
Configuring the I/O of the DMC-3425 with DB-14064 
The 64 extended I/O points of the DMC-3425 w/DB-14064 series controller can be configured in 
blocks of 8.  The extended I/O is denoted as blocks 2-9 or bits 17-80. 
The command, CO, is used to configure the extended I/O as inputs or outputs.  The CO command has 
one field: 
 
CO n 
 
Where, n is a decimal value, which represents a binary number.  Each bit of the binary number 
represents one block of extended I/O.  When set to 1, the corresponding block is configured as an 
output. 
Note: The CO command must be sent through the SA command to configure outputs for slave 
controller extended I/O. 
The least significant bit represents block 2 and the most significant bit represents block 9.  The decimal 
value can be calculated by the following formula.  n = n
2
 + 2*n
3
 + 4*n
4
 + 8*n
5
 +16* n
6
 +32* n
7
 +64* 
n
8
 +128* n
9
 where n
represents the block.  If the n
x
 value is a one, then the block of 8 I/O points is to 
be configured as an output.  If the n
x
 value is a zero, then the block of 8 I/O points will be configured 
as an input.  For example, if block 4 and 5 is to be configured as an output, CO 12 is issued. 
 
8-Bit I/O Block 
Block 
Binary Representation 
Decimal Value for Block 
17-24 2 
2
0
 
25-32 3 
2
1
 
33-40 4 
2
2
 
4   
41-48 5 
2
3
 
8  
49-56 6 
2
4
 
16 
57-64 7 
2
5
 
32 
65-72 8 
2
6
 
64 
73-80 9 
2
7
 
128 
The simplest method for determining n:    
Step 1. Determine which 8-bit I/O blocks to be configured as outputs.   
Step 2. From the table, determine the decimal value for each I/O block to be set as an output.   
Step 3.  Add up all of the values determined in step 2.  This is the value to be used for n.