For example, if block 8 is configured as an output, the following command may be issued: 
OP 7,,,,7 
This command will set bits 1,2,3 (block 0) and bits 65,66,67 (block 8) to 1.  Bits 4 through 8 and bits 
68 through 80 will be set to 0.  All other bits are unaffected. 
When accessing I/O blocks configured as inputs, use the TIn command.  The argument 'n' refers to the 
block to be read (n=0,2,3,4,5,6,7,8 or 9).  The value returned will be a decimal representation of the 
corresponding bits. 
Individual bits can be queried using the @IN[n] function (where n=1 through 8 or 17 through 80).  If 
the following command is issued; 
 MG 
@IN[17] 
the controller will return the state of the least significant bit of block 2 (assuming block 2 is configured 
as an input).  
 
Connector Description: 
The DMC-3425 controller with DB-14064 has two 50 Pin IDC header connectors.  The connectors are 
compatible with I/O mounting racks such as Grayhill 70GRCM32-HL and OPTO-22 G4PB24.   
Note for interfacing to OPTO-22 G4PB24:  When using the OPTO-22 G4PB24 I/O mounting rack, 
the user will only have access to 48 of the 64 I/O points available on the controller.  Block 5 and Block 
9 must be configured as inputs and will be grounded by the I/O rack. 
 
J6    50-PIN IDC   
Pin 
Signal 
Block 
Bit  @IN[n], 
@OUT[n] 
Bit No 
1. I/O 4 
40  7 
3. I/O 4 
39  6 
5 I/O 
38  5 
7. I/O 4 
37  4 
9. I/O 4 
36  3 
11. I/O 4 
35 
13. I/O 4 
34 
15. I/O 4 
33 
17. I/O 3 
32 
19. I/O 3 
31 
21. I/O 3 
30 
23. I/O 3 
29 
25. I/O 3 
28 
27. I/O 3 
27 
29. I/O 3 
26 
31. I/O 3 
25 
33. I/O 2 
24 
35. I/O 2 
23 
37. I/O 2 
22 
39. I/O 2 
21 
41. I/O 2 
20 
43. I/O 2 
19 
45. I/O 2 
18 
47. I/O 2 
17 
49. +5V -