Chapter 2 Getting Started
• 35
SP 5000
Set speed
BGA Start
motion
AD 4000
Wait until A moved 4000
TPA Tell
position
EN End
program
To start the program, command:
XQ #B
Execute Program #B
Example 12 - Control Variables
Objective: To show how control variables may be utilized.
Instruction Interpretation
#A;DP0
Label; Define current position as zero
PR 4000
Initial position
SP 2000
Set speed
BGA Move
AMA
Wait until move is complete
WT 500
Wait 500 ms
#B
V1 = _TP
V1 = _TP
Determine distance to zero
PR –V1/2
Command move 1/2 the distance
BGA Start
motion
AMA After
motion
WT 500
Wait 500 ms
V1=
Report the value of V1
JP #C, V1=0
Exit if position=0
JP #B
Repeat otherwise
#C;EN End
To start the program, command
XQ #A
Execute Program #A
This program moves the motor to an initial position of 4000 and returns it to zero on increments of half
the distance. Note, _TP is an internal variable that returns the value of the position. Internal variables
may be created by preceding a DMC-3425 instruction with an underscore, _.
the distance. Note, _TP is an internal variable that returns the value of the position. Internal variables
may be created by preceding a DMC-3425 instruction with an underscore, _.
Example 13 - Control Variables and Offset
Objective: Illustrate the use of variables in iterative loops and use of multiple instructions on one line.
Instruction Interpretation
#A
Set initial values
KI0
DP0
V1=8; V2=0
DP0
V1=8; V2=0
Initializing variables to be used by program
#B
Program label #B
OF V1
Set offset value
WT 200
Wait 200 msec