Chapter 2  Getting Started
  35 
SP 5000 
Set speed 
BGA Start 
motion 
AD 4000 
Wait until A moved 4000  
TPA Tell 
position 
EN End 
program 
To start the program, command: 
XQ #B 
Execute Program #B 
Example 12 - Control Variables 
Objective:  To show how control variables may be utilized.  
Instruction Interpretation 
#A;DP0 
Label; Define current position as zero 
PR 4000 
Initial position 
SP 2000 
Set speed 
BGA Move 
 
AMA 
Wait until move is complete 
WT 500 
Wait 500 ms 
#B  
V1 = _TP 
Determine distance to zero 
PR –V1/2 
Command move 1/2 the distance 
BGA Start 
motion 
AMA After 
motion 
WT 500 
Wait 500 ms 
V1= 
Report the value of V1 
JP #C, V1=0 
Exit if position=0 
JP #B 
Repeat otherwise 
#C;EN End 
To start the program, command 
XQ #A 
Execute Program #A 
This program moves the motor to an initial position of 4000 and returns it to zero on increments of half 
the distance.  Note, _TP is an internal variable that returns the value of the position.  Internal variables 
may be created by preceding a DMC-3425 instruction with an underscore, _. 
Example 13 - Control Variables and Offset 
Objective:  Illustrate the use of variables in iterative loops and use of multiple instructions on one line. 
Instruction Interpretation 
#A 
Set initial values 
KI0  
DP0  
V1=8; V2=0 
Initializing variables to be used by program 
#B 
Program label #B 
OF V1 
Set offset value 
WT 200 
Wait 200 msec