Galil DMC-3425 Manual De Usuario

Descargar
Página de 210
78 • Chapter 6  Programming Motion 
 
DMC-3425 
COUNT=0 Initialize 
Counter 
N=10 
Initialize position increment 
#LOOP LOOP 
VA [COUNT]=N 
Fill Array VA 
VB [COUNT]=N 
Fill Array VB 
N=N+10 Increment 
position 
COUNT=COUNT+1 Increment 
counter 
JP #LOOP,COUNT<750 
Loop if array not full 
#A Label 
LM AB 
Specify linear mode for AB 
COUNT=0 
Initialize array counter 
#LOOP2;JP#LOOP2,_LM=0 
If sequence buffer full, wait 
JS#C,COUNT=500 
Begin motion on 500th segment 
LI VA[COUNT],VB[COUNT] 
Specify linear segment 
COUNT=COUNT+1 Increment 
array 
counter 
JP #LOOP2,COUNT<750 
Repeat until array done 
LE 
End Linear Move 
AMS 
After Move sequence done 
MG "DONE" 
Send Message 
EN End 
program 
#C;BGS;EN 
Begin Motion Subroutine 
Vector Mode: Linear and Circular Interpolation (Local Mode) 
The DMC-3425 allows a long 2-D path consisting of linear and arc segments to be prescribed.  Motion 
along the path is continuous at the chosen vector speed even at transitions between linear and circular 
segments.  The DMC-3425 performs all the complex computations of linear and circular interpolation, 
freeing the host PC from this time intensive task. 
The coordinated motion mode is similar to the linear interpolation mode.  Any pair of two axes may be 
selected for coordinated motion consisting of linear and circular segments.  Note that only one pair of 
axes can be specified for coordinated motion at any given time. 
Specifying Vector Segments 
The motion segments are described by two commands; VP for linear segments and CR for circular 
segments.  Once a set of linear segments and/or circular segments have been specified, the sequence is 
ended with the command VE.  This defines a sequence of commands for coordinated motion.  
Immediately prior to the execution of the first coordinated movement, the controller defines the current 
position to be zero for all movements in a sequence.  Note:  This ‘local’ definition of zero does not 
affect the absolute coordinate system or subsequent coordinated motion sequences.  
The command, VP a,b specifies the coordinates of the end points of the vector movement with respect 
to the starting point.  The command, CR r,
θ,δ
 define a circular arc with a radius r, starting angle of 
θ
and a traversed angle 
δ
.  The notation for 
θ
 is that zero corresponds to the positive horizontal direction, 
and for both 
θ
 and 
δ
, the counter-clockwise (CCW) rotation is positive.