Graco P39LCS Manual De Usuario

Descargar
Página de 40
Installation 
10
312376L
System Accessories
 
Be sure all air lines (T) and fluid lines (S) are properly 
sized and pressure-rated for your system. Use only 
electrically conductive hoses. Fluid hoses must have 
spring guards on both ends.
Mounting Accessories
Mount the pump package to suit the type of installation 
Refer to Check-Mate Displacement Pump manual 
312375 for mounting hole layout.
to see air line accessories represented in a typical sup-
ply unit installation. 
Main air shutoff valve (W) isolates the air line 
accessories for servicing. Locate upstream from all 
other air line accessories. 
Air line filter (V) removes harmful dirt and moisture 
from the compressed air supply. Also, install a drain 
valve at the bottom of each air line drop, to drain off 
moisture.
Air regulator (G and AH) controls pump speed and 
outlet pressure by adjusting the air pressure to the 
pump. Locate the regulator close to the pump, but 
upstream from the bleed-type master air valve.
Air motor valve (AJ) is required in your system to 
shut off the air supply to the pump (see WARNING). 
When closed, the valve will bleed off all air in the 
pump. Be sure the valve is easily accessible from 
the pump. 
Pump runaway valve (AK) senses when the pump 
is running too fast and automatically shuts off the air 
to the motor. A pump which runs too fast can be 
seriously damaged. Locate in the position shown.
Pump bleed valve (P) is required in your system to 
relieve fluid pressure in hose and gun (see WARN-
ING). 
to see fluid line accessories represented in a typical 
supply unit installation. 
Install a fluid shutoff valve at each gun/valve drop, 
to isolate the gun/valve and fluid accessories for 
servicing.
Install a fluid drain valve near the pump fluid outlet, 
and at each gun/valve station. The drain valves are 
required in your system to relieve fluid pressure in 
the displacement pump, hose and gun/valve (see 
WARNING). Drain valves at the gun/valve stations 
may be mounted in the base of a fluid regulator, 
using an adapter.
Fluid regulator controls fluid pressure to the 
gun/valve, and dampens pressure surges.
Gun or dispense valve dispenses the fluid.
Gun/valve swivel allows freer gun/valve movement.
A main air bleed valve and pump bleed valve (P) are 
required. These accessories help reduce the risk of 
serious injury, including fluid injection and splashing of 
fluid in the eyes or on the skin, and injury from moving 
parts if you are adjusting or repairing the pump.
The main air shutoff valve shuts off the air to the pump 
and ram. The air motor valve relieves air trapped 
between this valve and the pump after the air is shut 
off. Trapped air can cause the pump to cycle unexpect-
edly. Locate the valve close to the pump. 
The pump bleed valve assists in relieving fluid pressure 
in the displacement pump, hose, and gun/valve. Trig-
gering the gun/valve to relieve pressure may not be 
sufficient.
If using Check-Mate pump with Graco Supply Sys-
tems, refer to Supply Systems Operation manual 
for system accessory installation instructions.
For use with all other systems, use this section for 
accessory installation instructions.